Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4352949 |
|---|---|
| Organisation Name | Postgraduate Institute Of Medical And Education And Research |
| Tender Brief | Corrigendum : Upgradation New Hybrid Passive Active Power Factor Correction For 10 Nos. 11 Kv Substations, Pgimer, Chandigarh |
| Last Date For Submission | 8th Jul, 2026 |
| Opening Date | 09 Jul, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 882000.00 |
| Estimated Cost | 44100874.00 |
| City | Chandigarh |
|---|---|
| State | Chandigarh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Hybrid Power Factor Correction Panel | ||
| 2 | Design, Supply, Installation, Testing & commissioning of cubicle type Semi compartmentalized floor mounted free-standing type with separation system Hybrid APFC panel. Hybrid panel should have, 433V, 50HZ, 3 phase 4 wire/3 Wire supply. Active part should be modular and have modules of 50/100 A or mentioned in specs, AHF must be intrinsic design of voltage sourced IGBT based intelligent 3-Level topology with 12 IGBT's with Programmable Microprocessor Controller to maintain Power Factor, Harmonics & Unbalancing. The passive part must be as per IS: 16636:2017 or IEC 61921 & 61439 Part -I & II (OEM Factory made) with valid temperature rise test from CPRI/ASTA-ERDA. The passive part must be as per the duly housed in epoxy powder coated 2mm thick CRCA steel sheet semi compartmentalized enclosure free standing type with all supports, accessories, switch gears, capacitors, control gears, protections, wiring, interconnections, control MCBs, controllers, reactors, etc. | ||
| 3 | All Major components like Capacitor, Reactors, Controller, Capacitor Duty Contactor and AHF module should be of single manufacturer for better operation and maintenance practice. All capacitors should be ISI/BIS Marked with valid CML Number on each name plate. All detuned reactors shall be with CE marking and ROHS compatible, IEC-60529, Electromagnetic standard FCC 15J,Class-A IEC61000-4, ANSI IEEE Standard 519-2014 (Harmonics LIMITS) items like capacitors should have valid CPRI type tested as per the relevant IS. Hybrid Panel should be IP-42 and duly housed in epoxy powder coated 2mm thick CRCA sheet steel semi compartmentalized enclosure free standing type with all supports, accessories, switch gears, control gears, protections, wiring, interconnections, control MCBs and maintain PF,I-THD,V-THD as per IEEE 519-92 etc. as required. Also complete in all respects & having its main components as bellow along with all other standard components ,circuitry & specifications as required: | ||
| 4 | NOTE:1) CT,VT for power factor measurement source side also consider in all panels. | ||
| 5 | Hybrid Power Factor Correction Panel AHF(300 Amp) + (APFC) 450 KVAR |
29 Days Left