| Tender ID | 4330643 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/maintenance Of Fire Detection, Alarm And Firefighting System Of Map Accn Under Ge (utilities) Udhampur |
| Last Date For Submission | 15th Jun, 2026 |
| Opening Date | 17 Jun, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 90000.00 |
| Estimated Cost | 4500000.00 |
| City | Udhampur |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply, fixing and testing of conventional manual call point 24V resettable type, each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion complete all as specified and directed by the Engineer-in-Charge. | 120.00 | Each |
| 2 | Repairing and testing of existing unserviceable and manual call point including opening, soldering of circuits, cleaning, replacement of glass, testing and painting complete all as specified and directed by Engr-in-Charge. | 60.00 | Each |
| 3 | Supply fixing and testing loop powered sounder strobe 24V. Dual tone hooter shall be of electronic type and shall give discontinuous/ intermittent audible alaram. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion and complete all as specified and directed by the Engineer-in-Charge. | 120.00 | Each |
| 4 | Dismantling the existing loop sounder by disconnecting device by movable ladder, dismantling cap & sensor board, cleaning the parts using CRC solution and check the control wiring circuit the PCB board , communication panel, device controlled by a programme, device sound & fire red flash light indication while fire activate and re addressing & re installation work complete all as specified and directed by the Engineer-in-Charge. | 60.00 | Each Job |
| 5 | Programming the main fire alarm panel, detecting the device activating the sounder according to the device, checking the communication between the all the device, fire alarm and main panel using ladder, making main fire alarm to normal display without any fault complete all as specified and directed by the Engineer-in-Charge. | 32.00 | Each Job |