Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3780451 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Providing Installation Testing And Commissioning Of Ivrf Systems New Ss Building Agmc Hospital Agartala Along With Operation For 4 Years After Installation And Comprehensive Maintenance For 3 Years After Post Installation Warranty Of 1 Year |
| Last Date For Submission | 8th Apr, 2026 |
| Opening Date | 08 Apr, 2026 |
| Document Cost | 8000.00 |
|---|---|
| EMD | 346377.00 |
| Estimated Cost | 17318830.00 |
| City | Agartala |
|---|---|
| State | Tripura |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant, vibration isolators, suitable foundation etc complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50 C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The units shall be of latest technology/latest generation of VRF system of the manufacturer and in successful operation for at least last three years. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Individual Circuit and its Combination of single module units shall be as per approval of the engineer-in-charge. | 340 | HP |
| 2 | Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature of following minimum capacity. | ||
| 3 | 2.0 TR | 2 | Nos |
| 4 | 2.4 TR | 1 | No |
| 5 | 2.6 TR | 16 | Nos |