Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3489097 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Provn Of Flame Proof Air Conditioners At Stn Armoury And Aerolube Store At Af Stn Sonegaon |
| Last Date For Submission | 25th Mar, 2026 |
| Opening Date | 01 Apr, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 28860.00 |
| Estimated Cost | 1443000.00 |
| City | Agra |
|---|---|
| State | Uttar Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | S&F flame proof 1.5 TR Split Air conditioner as per relevant IS complete suitable for single phase 240VAC, 50 Hz alongwith the flame proof condennsing unit, Cooling unit, Flame proof control panel, thermostat unit, FLP junction boxes any way, suitable size copper cable inside the mettallic conduit and suitable size copper tube from condensor to cooling unit and back Complete. Make Shyaam Switchgear Cat part no. SSPL/HC/508 or equivalent in Sudhir/flexpro including following specifications:- (i) Condensing Unit:- The condensing unit consist of Emersion make hermetically sealed explosion proof compressor with R407C eco friendly refrigerant, condensor motor, condensing coil with copper tubes and aluminium blue fins duly coated with specialist checal to prevent refrigerant leakage and whole unit accommodated inside the stainless steel SS304 enclosure. (ii) Cooling Unit:- The indoor mounted to be kept in hazardous area of split cooling unit, cooling motor, cooling coil with copper tubes and aluminium blue fins duly coated with specialist checal to prevent refrigerant leakage and whole unit accommodated inside the stainless steel SS304 enclosure. | 3.00 | Each |
| 2 | Contd....from item No 1.00 (iii) Flameproof Control Panel:- The control panel consist of lamps 230 volts AC - 05 Nos (Power ON, Compressor motor ON, Compressor Trip and cooling motor trip) with temparature indicator, 2 relay output, FLP RTD PT100 3 wire. MCB, Contactor and over load relay for protection of compressor and condensor motor, cooling motor and incomer MCB wiil be provided. (iv) The rate quoted by the contractor shall include the rate for suitable size wall mounting bracket/frame by using metal bracket/ angle iron frame duly painted with two coat of rust proof paint over the coat of red oxide primer. Tha drain out pipe made up of GI pipe of size 15mm dia of suitable length as site requirement. | ||
| 3 | M&L for Flame Proof sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core HFFR of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed HFFR with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including consealed 20 mm dia steel conduit complete all as specified and as directed. Make:- Plaza / Havells / Polycab / FINOLEX | 391.00 | RM |
| 4 | Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250 volt 2P +earth. | 3.00 | Each |
| 5 | Supply and fixing Flame proof weather proof distribution board SPN 4 way with incoming MCB 2 pole 32 amps - 01 Nos and outgoing MCB 1 pole 16 amp - 02 Nos complete all as per Shyaam cat part No - SSPL/CS/174 or equivalent as approved. | 2.00 | Each |