Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3504654 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair To Building No P132 Or Md Accn And Provn Of Washing Bay At Tk Tptr Pl And Metal Gate At Fs Unit Under Ge North Akhnoor |
| Last Date For Submission | 26th Mar, 2026 |
| Opening Date | 28 Mar, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 97200.00 |
| Estimated Cost | 4860835.00 |
| City | Akhnoor |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Demolition of existing old tarfelt, water proofing membrane including roof tiles, cement mortar screed, concrete base of any thickness and roughing surfaces to receice roof treatement including removal of debris from MoD land, complete all as specified and directed. | 128.00 | Sqm |
| 2 | Rendering 15mm thick cement plaster with cement mortar(1:3) on fair finishes of brick work or concrete surface of roof slab, using WPC to be measured seperately under relevant item in schedule complete all as specified and directed. | 128.00 | Sqm |
| 3 | Supply only integral water proofing compound | 5.00 | ltr |
| 4 | Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Covered fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Quoted rates are inclusive of all of the above work. (ii) Water proofing treatment shall only be carried out by the authorised personal of the Company and proper record of the same shall be maintained. | 128.00 | Sqm |
| 5 | PCC 1:2:4, B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed | 13.51 | Cum |
6 Days Left