| Tender ID | 3659354 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Corrigendum : Repair And Renovation Work For Psychiatry Department At Burdwan Mch, Purba Bardhaman -- Supply, Installation, Testing and Commissioning Of Ac Machine. |
| Last Date For Submission | 10th Apr, 2026 |
| Opening Date | 13 Apr, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 62900.00 |
| Estimated Cost | 0.00 |
| City | Bardhaman |
|---|---|
| State | West Bengal |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of 5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr (17.58KW) with 2 Nos. compressor (Rotary / Twin Rotary / Scroll), 2 nos. 2.5 TR each IDU of rated power supply - 240V (+/-5%), 1ph, 50Hz., 1no. ODU of rated power supply - 415V(+/-5%), 3ph, 50Hz. Air-flow/per IDU :- 1000CFM. Refrigerant R32 / R410A. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 2.0000 | Nos |
| 2 | Supply, Installation, Testing & Commissioning of 3 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr (10.54 KW) with 2 Nos. compressor (Rotary / Twin Rotary / Scroll), 2 nos. 1.5 TR each IDU of rated power supply - 240V (+/-5%), 1ph, 50Hz., 1no. ODU of rated power supply - 415V(+/-5%), 3ph, 50Hz. Air-flow/per IDU :- 650CFM. Refrigerant R32 / R410A. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 1.0000 | Nos |
| 3 | Supply, Installation, Testing & Commissioning of 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr (7032 watts). with 1 No. Rotary compressor with R410A/R32 Refrigerant,1 nos. IDU of rated power supply-230V-1ph-50Hz, 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 800 CFM.copper condenser. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Outdoor unit must be fixed with suitable size bracket/ angle iron frame. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 3.0000 | Nos |
| 4 | Supply, Installation, Testing & Commissioning of 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr (5274 watts). with 1 No. Rotary compressor with R410A/R32 Refrigerant,1nos. IDU of rated power supply-230V-1ph-50Hz, 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM.copper condenser. The indoor unit must be suspended from ceiling / wall with all necessary structure as per requirement and tie rod incl. necy. Outdoor unit must be fixed with suitable size bracket/ angle iron frame. Painting as per direction of EIC. PCB of the AC unit must be enclosed in Metal Enclosure to prevent fire. (Make : Hitachi / O-General / Mitshubishi Electric / Daikin as per direction of EIC). | 13.0000 | Nos |
| 5 | Supply, installation & commissioning of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall. |