Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3490500 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair To E/m Plant And Machinery At Mil Stn Sgnr |
| Last Date For Submission | 25th Mar, 2026 |
| Opening Date | 27 Mar, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 101438.00 |
| Estimated Cost | 0.00 |
| City | Ganganagar |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking up old unserviceable DG set by dismantling it from the Foundation, taking out electrical connection,earthing, Fuel connection from fuel tank, exhaust pipe and deposited to MES Yard complete all as specified and directed. | 2.00 | Each Job |
| 2 | Taking down old unservieable LT cable of any size and capacity complete all as specified and directed. | 120.00 | RM |
| 3 | Supply, installation, testing and commissioning of "Silent type" (accoustic enclosure type as per NBC 2016), as per CPCB- IV+ compliant or latest CPCB norm, Diesel engines shall be as per MOEF (MINISTRY OF ENVIRONMENT, FOREST AND CLIMATE CHANGE) notification dtd. 3rd November 2022.Diesel Engine driven Generating set of capacity 82.5 KVA, 415 Volts 3 phase 4 wire 0.8 power factor and 1500 RPM at NTP electrical start, directly coupled and mounted on common base frame with coupling of suitable size to water cooled turbo charged diesel engine of suitable BHP as per IS: BS5514 / ISO 3046 and alternator as per IS-13364, IS/IEC:60034-1 complete with foundation, AVM pads, control panel, fuel tank of suitable capacity with fuel lines of heavy duty MS pipe duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and suitable batteries of capacity as recommended by manufacturer fixed on angle iron frame with necessary meters and sound proof canopy and separate battery charging system of suitable capacity with all standard accessories, tool box and tools as provided by the manufacturer complete all as specified and directed. | 2.00 | Each Job |
| 4 | (A) Prime Mover: Vertical diesel engine of suitable capacity water cooled,Radiator mounted close circuit as per BS 649 , IS 10002 , ISO- 8528 or equivalent direct injection type turbo charged. The DG set shall be capable of running 24 hours on full load. Engine shall be equipped with all standard fittings as permanufacturer's recommendation and mounted on common base frame with following:- (a) RPM cum Hour meter (b) Battery charging alternator with inbuilt regulator (c) Ignition and starting keys with push button switch (d) Lubricating oil pressure gauge, oil and water temperature gauges (e) Batteries as recommended by manufacturer with battery leads of suitable size of copper cable (f) Self starter motor of suitable capacity (g) PCC Foundation for Generating set as per recommendation of manufacturer (h) Exhaust pipe duly insulated with asbestos rope for thermal insulation (j) Exhaust silencer industrial type to maintain noise level (k) Over speed indication (l) Low lubrication, oil trip indication (m) Engine Hours indication (n) Digital Amp meter and Voltmeter | ||
| 5 | (B) Alternator:- Synchronous alternator of rating 82.5 KVA DG set, 3 phase, 50 cycle, 415 volts, 4 wire AC supply 0.8 PF at NTP for running at 1500 RPM self excited, self regulated, screen protected, brushless type mounted on common base frame coupled with above Engine. The alternator shall be conforming to IS 60034-1 / BS 2613 suitable for tropical conditions and with class F/H insulation. Note:-DG losses, monitoring as per ECBC 2017 Standard. (C) Contol Panel and AMF Panel:- Control panel and outdoor type AMF panel, 415 Volts, 3 phase, 4 wire, 50 cycles fabricated out of 3.15mm outer shell thick MS shee and 2 mm inner shell thick MS sheet and powder coated painted internally and externally complete with copper bus bars with suitable capacity with incoming / outgoing terminals control wiring with copper cable of suitable size for DG set including all engine and alternator control switches and indicator as per manufacturer design and comprising of the following:- (a) MCCBs of 125 Amps capacity, 415 Volts, 4 pole, 16 KA for incoming/outgoing with over load and short circuit protections - 03 Nos (b) Voltmeter and Ammeter with selector switches and CTs of suitable capacity (c) Power factor and frequency, RPM, running hours counter, water tempreture, lub oil pressure meters (d) Indicating lamps (LED type) to indicate RYB and for load on and set running battery charger ON (e) Failure indication (LED type) over/ under speed, fail to start, low oil pressure, battery charger failure (f) Engine start and stop push buttons (g) Battery charging indicator lamp 01 No |
6 Days Left