Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3490533 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair And Maint Of Geyser Ceiling Fan Exhaust Fan Desert Cooler Split/window Ac Refrigerator Deep Freezer Water Cooler Electric Meter And Internal Electrification Incl Miscellaneous Items And Repair And Maint Of External Water Supply Distribution System Repl |
| Last Date For Submission | 25th Mar, 2026 |
| Opening Date | 27 Mar, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 100000.00 |
| Estimated Cost | 4983000.00 |
| City | Gurgaon |
|---|---|
| State | Haryana |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Material and labour for checking loose connections, sparks,earth leakage etc by disconnecting and taking down the swiches /switch boards/LEDs/Fans/DBs /fixtures etc and making good by clearing the fault, making proper insulation and testinng and restoring the supply etc all as directed. Note-i) Replacement of any part such as switches, sockets, tube lights,DBs , MCBs shall be measured and paid seperately under relevent items. | 800.00 | Each Job |
| 2 | Taking down carefully point wiring removing from site of work and making good to the disturbed surfaces of walls/floors etc all as specified and directed. | 770.00 | Per Point |
| 3 | Taking down carefully MCB Distribution board SPN/TPN off sizes & any capacity by unscrewing from DB box, all as directed. | 78.00 | Each |
| 4 | M&L Point wiring for One light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including PVC concealed rigid conduit (ISI mark) and pressed steel terminal boxes (for mounting switches / sockets /regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm and 6cm depth including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed . Note :- (i)The wiring shall be provided in standard colour code (ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces. (iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed. (iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed. | 150.00 | Per Point |
| 5 | All as per description of serial item No. 4.00 here in before but for One 3-pin socket outlet 5 Amp on independent board. | 100.00 | Per point |