Tender BriefAssessment Of Load Carrying Capacity Of Existing Ist And Iiird Floor Data Center It Building At Yojana Bhawan Jaipur
Last Date For Submission24th Mar, 2026
Opening Date24 Mar, 2026
Cost
Document Cost500.00
EMD1.00
Estimated Cost210000.00
Location
CityJaipur
StateRajasthan

Register to see full details

BOQ Items
#ItemQtyUnits
1Conducting detailed survey of building by visual inspection & submission of preliminary report covering basement, Ground Floor , Ist Floor and IIIrd Floor area of State Data Center a. External faces, Column, Beam, Roof Slab areas.1.00Job
2Rebound Hammer Test: Preparing the surface of RCC structural members such as beams, columns, labs etc. by chipping the plastered surface/finishing/cladding to expose the concrete, smoothening the area using carborundum stone all in terms of relevant IS code and conducting rebound hammer test all as per IS 13311-1992 (Part 2) or as directed by consultant including analysis of the test result& preparation of separate report for each building with observations and recommendations for remedial measures if any. Nos test to be done as per codel provision/site requirement provision.40.00Nos
3UPV(UltrasonicPulseVelocity)Test: Preparing the surface of RCC structural members such as beams, columns, slabs etc. by chipping the plastered surface/finishing/cladding to expose the concrete, smoothening the area using carborundum stone all in terms of relevantIS Code and conducting UPV all as per IS 13311-1992(Part1)or as directed by consultant including analysis of the test result & preparation of separate report for each building with observations and recommendations for remedial measures if any.46.00Nos
4Half Cell Potential Test for Corrosion mapping: Preparing the structural members as directed to expose the reinforcement steel, cleaning the area with blower/wire brush and carrying out half-cell potentiometer test for measuring the level of corrosion of reinforcement steel in the RCC member including analysis of the test result& preparation of separate report for each building with observations and recommendations for remedial measures if any.5.00Nos
5Carbonation Depth Test: Preparing the surface of RCC structural member such as beams, columns, slabs, water tank walls & slab etc. by chipping the plastered surface/finishing/cladding to expose the concrete, cutting etc. as per relevant code and conducting carbonation test at various depth as directed by consultant using phenolphthalein of Specified concentration to assess depth of carbonation including analysis of the test result & preparation of separatereport foreachbuilding with observations and recommendations for remedial measures if any.5.00Nos