| Tender ID | 3688116 |
|---|---|
| Organisation Name | Indian Institute Of Technology |
| Tender Brief | Corrigendum : Supply, Installation, Testing and Commissioning Of 4 X 4 Tr Tower Acs With Associated Works At Dinning Hall In Visitors Hostel At Iit Kanpur |
| Last Date For Submission | 30th Mar, 2026 |
| Opening Date | 31 Mar, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 12180.00 |
| Estimated Cost | 608966.00 |
| City | Kanpur |
|---|---|
| State | Uttar Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply , Installation, testing & commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section). R-32/R410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 415 10% Volt with low & high voltage cutoff and 50 hz ,3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified.The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per Institute specification and as per IS: 1391 as required. | ||
| 2 | 4.0 TR Cooling Only | 4.00 | Nos. |
| 3 | Providing & fixing Unplasticized Polyvinyl Chloride (uPVC), having thermal stability for cold water supply, including all uPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer In Charge. Internal Work - Exposed on Wall | ||
| 4 | 25 mm nomial outer dia pipes | 15.00 | Mtr |
| 5 | Supply & fixing of of angle iron frame made of 25/32 mm thickness 5 mm for mounting of outdoor unit size, duly painted and finished with canopy and vibration isolation pad if required complete as reqd for Tower AC |