Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Indian Institute Of Technology
Tender ID3691856
Organisation NameIndian Institute Of Technology
Tender BriefCorrigendum : Supply, Installation, Testing and Commissioning Of 9 X 1.5 Tr Split Ac Hot And Cold In Standard Room With Associated Works In Visitors Hostel At Iit Kanpur
Last Date For Submission30th Mar, 2026
Opening Date31 Mar, 2026
Cost
Document Cost0.00
EMD8904.00
Estimated Cost445216.00
Location
CityKanpur
StateUttar Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners with Indoor Unit (IDU), Outdoor unit (ODU), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe or as provided by OEM, R-32/R-410/R- 407 Green refrigerant, wireless remote control with cells, sutiable for working between 180-260 V with low & high voltage cutoff and 50 Hz , 1 phase AC supply capable of performing cooling, dehumdification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of rated capacity upto 52 C . Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must Comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermietic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391Part ll 2023.
2Inverter Type - Hot & Cold
31.5 TR with 3 star BEE rating9.00Nos.
4Providing & fixing of additional refrigerant copper piping (6.3 mm/15.88mm) or (6.3 mm/12.7 mm) suitable for suction & discharge line i/c additional refrigerant R-32 /R-410 A top-up as required with 6/9 mm XLPE/Nitrile insulation with PVC tape on surface /recessed with clamps, screws etc from indoor tooudtdoor units as standard specifications complete as required1.00Mtr
5Providing & fixing Unplasticized Polyvinyl Chloride (uPVC) pipes, having thermal stability for cold water supply, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer In Charge. Internal Work - Exposed on Wall
30th Mar, 2026

6 Days Left