Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Public Works Department
Tender ID3246019
Organisation NamePublic Works Department
Tender BriefCorrigendum : Construction Of College Building (second Campus) (g Plus 5) Upto Third Floor At Mrinalini Datta Mahavidyalaya, Ninmta, Kolkata-700049-- Supply, Installation, Testing and Commissioning Of Dg Set.
Last Date For Submission13th Apr, 2026
Opening Date17 Apr, 2026
Cost
Document Cost0.00
EMD36800.00
Estimated Cost0.00
Location
CityKolkata
StateWest Bengal

Register to see full details

BOQ Items
#ItemQtyUnits
1SITC OF 100KVA DG: Supply, Instalation ,Testing and Commisioning at site of 100 KVA, 415V, 50Hz, 3Phase silent new DG Set, comprising of Engine, alternator, integrated AMF panel, Base frame, Fuel tank, Battery, CPCB-IV+ approved Engine & Acoustic Enclosure having following specifications. ENGINE Make- Cummins/Greaves Power/Ashok Leyland/Greaves Cotton) Engine Type : 4 Stroke Diesel Engine, RPM 1500 Rated Output: 122 BHP or Higher, Duty: PRIME Cooling : Liquid cooled/radiator cooled Cylinder: 4, In-line Aspiration : Turbo Charged Type of Govemer : Electronic Fuel Tank Capacity Minimum capacity 160 Ltr as per manufacturer's standard Ltrs. Fuel Consumption at 75% rated Load with Radiator or Fan: As per Manufacturer's standard 16.5Ltr/ Hr. or Less, Fuel Consumption at 100% rated Load with Radiator or Fan : As per Manufacturer's standard 22 Lt/ Hr or Less Overload Capacity: 10% overload for one hour for every 12 hours continuous running at full load or better. Engine instrument Panel : Consisting of starting switch with Key. Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter. Safety Controls Emergency Stop. Low Lube Oil Pressure warning Shutdown, High Engine Water Temp. warning (Shutdown, Sensor failure Indicator, Engine over speed indicator Battery charging and low battery indicator Exhaust Silencer Residential Type Starting system: 12V starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard Battery Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning.1Item.
2ALTERNATOR Make : Stamford/Leroy Somer/Crompton Greavs Rating: 415 V, 3Ph. 50 Hz, 100 KVA,1500 rpm Type Brushless, self excited and self regulated Insulation Class H Protection :screen-protected drip proof ith Min.IP23 degree of protection RPM: 1500 Voltage Regulation (max): +1% Winding connection Star with Neutral Total Distortion factor Less than 3% Total Harmonic distortion in output waveform: 55% AMF PANEL Integrated AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 100 KVA DG set having following specification/features. i)160A MCCB with O/L S/C, E/F protection and microprocessor based protection release , UNreleased etc. -2 sets (L&T/Siemens/ABB) m) in Built By-Pass switch for rated capacity 2On -delay timer for load change over iv) On-delay timer for engine 3)Engine On-Off switch (Push button type) 1 Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine video Minimum five number indicating lamps to indicate 'mains JON load on mains, Set running, 'load on set' and 'battery charger on' video Audio visual alarm for 'Low lubricating oil pressure, 'High water temperature, Start failure, and DG overload load'. Mode selector for setting the panel on Auto/Man/ Test Mode. Microprocessor based relay with composite meter for digital display of following. Generator voltage/AC Mains voltage. Generator Current in all phases Frequency ,Power Factor Energy Indication for alternator supply Running time indications number of hours of operation and service intervals, service due indications the AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
3ACOUSTIC ENCLOSURE The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-IV norms. BASE FRAME Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting HookType. Rate should be quoted inclusive of all applicable taxes and Duty etc (i) All materials, equipments & accessories must conform to relevant IS /IEC specifications. (ii)The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer (iii) Necessary manufacturer's test certificate for Diesel Engine, alternator etc. Will have to submit in triplicate copy during delivery of the equipment iv) Copy of "Type Approval Certificate" and Certificate of Op must be produced at the time of delivery issued from competent Authority (As per CPCB-IV). (v) Circuit Diagram for AMF Panel must be submitted from thel stars Manufacturer / OEM. (v) The entire set must be warranted at least 15 months from the date of Delivery/24 months/ 5000 Hrs from the date off Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
4Making Brick foundation and R.C. casting and making neat cement finish after plastering for installation of AMF panel incl. S&F suitable M.S angle/Channel with nuts, bolts & washer etc. as per direction of EIC.1Job
5S & F M.S Exhaust Pipe of 150 mm dia. including connection with existing silencer and S & F Bend, flange, nuts, bolts and washers and necessary fixing materials as required including making necessary welding, as per direction of EIC.4RM.
13th Apr, 2026

19 Days Left