Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 2906000 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Corrigendum : Construction Of New Cardiology Icu At Seventh Floor Of Under Construction B C Roy New Building Bplus G Plus9 Building Under Nrsmc And H Kolkata Electrical Work Supply, Installation, Testing and Commissioning Of Ac Machine |
| Last Date For Submission | 10th Mar, 2026 |
| Opening Date | 12 Mar, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 26815.00 |
| Estimated Cost | 0.00 |
| City | Kolkata |
|---|---|
| State | West Bengal |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | FLOOR MOUNTED AIR HANDLING UNITS FOR cardiology ICU SITC of following Floor Mounted Modular Construction Double Skinned Air Handling Units (50 mm S.P.)with recommended Fresh Air arrangement each consisting of the following and having 25+2 mm thick PUF insulated extruded Aluminium section frame construction: a) Fan Section forward curve imported fan (MK.Krugar/Nikotra).The AHU shall consist of 1 no. Centrifugal Blower with 2 nos. (1W + 1S) TEFC Squirell cage induction motor. b) Coil section 6 Rows deep (0.41 mm thick), 11-13 FPI Coolig Coil with washable Pre-filters with efficiency 90% down to 10 microns. c) Set of Microvee Fine Filters with efficiency of 95% down to 5 Microns. d) TEFC sq,Cage Induction Motor. e) Sandwiched SS Drain Pan. The AHU shall be complete with VFD.The VFD shall be of IP20 rating.The AHU shhould be equipped with proper valves. f) Inner skin - 0.63 mm thick plain GI sheet. g) outer skin - 0.63 mm thick pre coated GI sheet. h) Provision for fixing of UVC Emitter. i) 11000 cfm, 6 row deep coil, 50 mm WC static pressure. | 1 | Set |
| 2 | SITC of UVC EMITTER for the above AHU's for prevention of fungus in the chilled water cooling coils. The minimum UV intensity in the coils shall be greater than 1000 uW/Cm2 for Ots. The unit shall be UL Listed (UL-1995) (MAKE-ALFA/RUKS/AEROPURE) | 1 | Set |
| 3 | SITC and insulating of following nominal sizes chilled water piping complete with fittings, supports, bends, elbows, flanges, insulation ets. With necessary clamps, vibration isolators and fittings duly insulated with 50 mm thick inside building/50 mm thick outside building TF quality expanded polystyrene foam in pipe section 16 kg/cum density covered with a layer of vapour barrier and covered with 12 mm thick sand cement plaster on GI chicken wire mesh. The pipes shall be of MSERW, "C" class as per IS 1239 and IS 3589 standards (for pipe sizes above 150 mm NB).(TATA) | ||
| 4 | 65 mm NB | 64 | Mtr |
| 5 | 100 mm NB | 35 | Mtr |
7 Days Left