| 1 | Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification . Make: Autronica/ Honneywell (Gamewell) / Bosch/ Salt/ Jade-Bird. | 1 | Each |
| 2 | Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) .Make: Autronica/ Honneywell (Gamewell) / Bosch/ Satel/ Jade-Bird. | 36 | Each |
| 3 | Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Autronica/ Honneywell (Gamewell) / Bosch/ Satel/ Jade-Bird. | 2 | Each |
| 4 | Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL/EN/VDS Certified.Make: Autronica/ Honneywell (Gamewell) / Bosch/ Satel/ Jade-Bird. | 4 | Each |
| 5 | SITC of Loop Powered Sounder cum Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should have IP40 or better protection rating be programmed from the panel. Shall be EN54 / Vds/UL Certification. Make: Autronica/ Honneywell (Gamewell) / Bosch/ Satel/ Jade-Bird. | 4 | Each |