Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4961831 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Addn Alteration Of Other Rank Cook House In Building No P-388 At Military Station Agartala |
| Last Date For Submission | 12th Aug, 2026 |
| Opening Date | 15 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 19040.00 |
| Estimated Cost | 952000.00 |
| City | Agartala |
|---|---|
| State | Tripura |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking out complete existing roof treatment from roof surface & roughening of old concrete floor surfaces incl cleaning the roof surfaces by brushing sweeping etc and removing rubbish n. exe 50 meter all as specified and directed | 5.00 | Sqm |
| 2 | M&L for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs cleaning out and tacked the polymeric membrane into the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc all as specified and directed | 5.00 | RM |
| 3 | M&L for 15mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for applying single component acrylic polymer modified, finished even and fair without using extra cement complete all as specified and as directed. (NOTE : Polymeric membrane shall be measured and paid separately under relevant item of this Schedule 'A'). | 5.00 | Sqm |
| 4 | M & L PCC (1:2:4) type B1 (20mm graded aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound in top layer @ 3% by weight of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement all complete as specified and as directed. (Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule 'A'). | 0.20 | Cum |
| 5 | M&L for clearing of plastered roof surface & applying one coat of cold bitumenous primer @ 0.25 lits per sqm conforming to IS 3384-1986, and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.50 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over Bitumenious primer (Application of polymerie memberane shall be by torch application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinal direction) coved fillet in PCC (1:2:4) type BO of radius 75 mm shall be provided at the junction ofroof& other vertical surfaces & applying one coat of aluminium paint over the APP nmodified membrane @ 0.11 kg/sqm all as speciied and directed. | 5.00 | Sqm |
6 Days Left