Tender ID4449245
Organisation NameMilitary Engineer Services
Tender BriefProvn Of Works Services For Soil Investigation At Af Station Jabalpur Under Age (i) Af Sonegaon
Last Date For Submission19th Jun, 2026
Opening Date26 Jun, 2026
Cost
Document Cost500.00
EMD65180.00
Estimated Cost3259000.00
Location
CityAgra
StateUttar Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1(A) MULTISTOREY STRUCTURE. Conducting soil investigation test at site as per relevant specification of IS-2131, IS-6403, IS-1498 & IS-2720 and submit the report as per following including shifting of equipment from one place to another place at any distance :- (A) Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instruction of the Eng-in-charge. Refusal defined as and when 'N' value is 100 or more for 30 cm or part penetration. (a) Conducting standard penetration test (SPT) in the bore holes at 1.00 m intervals in depth or every change of strata which ever is earlier as per IS:2131-1981or Condcuting dynamic cone penetration test (DCPT) in the bore holes at 1.00 m intervals in depth or every change of strate which ever is earlier as per IS:10042-1981 (Applicable for gravel, boulder deposit type of soil) (i) Depth of bore hole = 15 m (for multistorey str qty 05BHs (04 in each corner & 01 in centre) in one block bldg, raft/ Mat footings))5.0015RM
2(b) Collecting distrubed and undsturbed soil sample from the locatiion of conducting SPT/DCPT at an interval of 1.00 m depth or at change of strata whichever occurs earlier. (c ) Analysis of liquification potential for earthquake as per Zone-II of IS 1893-2016 (part-I). (d) Ground Water Table & HFL : (i) Maximum and minimum levels of ground water in the area with source of information. (ii) Ground water table observed during the investigation. (iii) Recording the ground water table if observed upto exploration depth, as per IS:6395-1973. (e) Disturbed soil samples : Following lab test to be conducted on disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- (i) Sieve analysis & Grain size distribution by Sieve analysis & hydrometer test (ii) Atterberg's limit as per IS:2720 Part-5-1985 (iii) Natural moisture content (iv) Particle size analysis test (v) Bulk density/dry density. (f) Undisturbed soil samples : Following lab test to be conducted on Un disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:-
3(i) Natural moisture content (ii) Bulk density (iii) Specific gravity (iv) Free swell index and swelling properties of soil (v) Organic matter in soil if any (vi) Consolidation test (compressed index value) (vii) Triaxial compression test and determination of shear parameters (C& test) as per relvant IS (viii) Harmful salt (complete investigation as already ref). (B) Submission of Six copies of ink signed test reports. The report should include the following (i) Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grain size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation. (ii) A detailed site plan showing the approx location of each bore duly numbered as per log of borehole should be enclosed with every site's soil investigation report. Location of foundation of adjacent structure, espacially those that might be impacted by the proposed construction should be indicated with details in site plan. (iii) The SBC of the soil is required to be given as per Sch 'A' Notes in tender documents, calculation of bearing capacity will be governed generally as per IS:8009 Part-1-1976, IS:2720 Part-2-1980, IS:6403-1980, IS:1904-1986 & IS:1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters/ indices shall be given in the soil report.
4(iv) Plotting of a complied sub surface profile along the depth in plan directions. (v) Photographic record of geo-explorations as well as testing shall also form part of the report.(min 04 Photographs). (vi) Every page of the Soil Investigation Report should have the Name of the Job for which Soil Investigation is being carried out. In case of multiple sites of a single Job are being investigated name of each site shall be put on each page of report pertaining to the site alongwith the name of the Job. (vii) The AGE (I) shall intimate the approximate type of construction, utilization and dimensions of proposed bldgs to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc) (viii) In case of underground building basement construction, or if requirement of temporary/permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations. Soil investigation report should be signed by M. Tech (Geotech).
5(ix) Depending on the soil conditins found at site , the consultant will recommend if any changes in the soil strata is required to strengthen the soil like use of soil stabilization technique or any other such methods. (x) All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the soil investigation. Report should be scrutinized by GE & CWE for correctness & endorsed. Note :- Transportation of equipment/mobilization/Dematerialization of equipment, etc forsoil investigation shall be deemed to be included in quoted rates.