Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID5026164
Organisation NameMilitary Engineer Services
Tender BriefRepair/ Maint To Mes Office Under Aor Age B/r-ii Of Ge (west) Agra
Last Date For Submission10th Aug, 2026
Opening Date17 Aug, 2026
Cost
Document Cost500.00
EMD60000.00
Estimated Cost0.00
Location
CityAgra
StateUttar Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Dismantling/ demolition of polymeric water proofing membrane single layer with and including plaster, PCC, Padding, brick coba etc on roofs complete including removal of material and debris away from the site etc complete all as specified and directed.120.00Sqm
2M&L for Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. Brush apply a bond coat of Pidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface complete all as specified and directed.120.00Sqm
3M&L for Laid to fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should be done for 7days. Air cure screed for 7days, before application of roof top coat coating system etc complete all as specified & directed.120.00Sqm
4M&L for Apply one coat of Cipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat of Roofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed.120.00Sqm
5M&L for brick work with sub class B bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 including demolition of old brick work built in CM complete all as specified & directed5.00Cum
10th Aug, 2026

20 Days Left

WhatsApp