Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID3816911
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Special Repair To Building No P-72 At Rlt Vihar And Provn Of Hot And Cold Water Cooler For Mh Under Ge (n) Akhnoor
Last Date For Submission21st Apr, 2026
Opening Date28 Apr, 2026
Cost
Document Cost500.00
EMD98500.00
Estimated Cost4921000.00
Location
CityAkhnoor
StateJammu and Kashmir

Register to see full details

BOQ Items
#ItemQtyUnits
1Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description and of any type over RCC roof including roof tiles, cement mortar screed of any thickness including making good the surface to receive new screed and removal of debris outside the MoD land complete all as specified and as directed.385.00Sqm
215mm thick plaster on roof / concrete surfaces incl parapet etc in cement mortar 1:3 and finished even and smooth without using extra cement and mixed with waterproofing compound as per manufacturers instructions. (Note. WPC shall be measured and paid separately).385Sqm
3Supply only liquid water proofing admixture conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement)15.00Ltr
4Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 150 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.385.00Sqm
5PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in roof kerb, padding , finished surface even and fair, complete all as specified and directed.10.00Cum
21st Apr, 2026

6 Days Left

WhatsApp