Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4449029 |
|---|---|
| Organisation Name | Indian Institute Of Science |
| Tender Brief | Corrigendum : Replacement Of Existing Outdoor Electrical Panel Near Parking Area Of J N Tata Auditorium And Replacement Of Bollard Lights And Cables In Front Of Digits At Iisc Bangalore. |
| Last Date For Submission | 8th Jun, 2026 |
| Opening Date | 09 Jun, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 0.00 |
| Estimated Cost | 0.00 |
| City | Bangalore |
|---|---|
| State | Karnataka |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Fabricating supplying and mounting MS box made out ....SWG suitablefor floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. Note : The Panel will be installed at External. Rate should be quoted for canopy with IP65. Also existing cables will be terminated at bottom of the panel. 14 SWG | 125,100 | Sq cm |
| 2 | Providing MS " C - Channel " - 75 x 40 *4.8/5/6 mm ( Rate inclusive of Fabrication & welding of MS - C - Channel including of all consumables, bolt, nuts, painted with 2 coats of red oxide and then two coats of approved paint as per Engineer in charge instructions. This MS "C- Channel" should be fixed at the bottom of the Electrical Panel - MS " C - Channel " - 75 x 40 *4.8/5/6 mm= 7.14 kg per meter x 4 mtr = 28.56 kgs | 28.56 | Kg |
| 3 | Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. And M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | 3.90 | Meter |
| 4 | Caution/Danger Board | 2 | No's |
| 5 | Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Shortcircuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 36kA, 4P - Make : Legrand, L&T, Schneider | 1 | Each |
3 Days Left