Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Jammu And Kashmir State Power Development Corporation
Tender ID4558120
Organisation NameJammu And Kashmir State Power Development Corporation
Tender BriefCorrigendum : Re Tubing Of Damaged Coolers (heat Exchangers) At 3into35 Mw Ljhp Power House Baramulla
Last Date For Submission10th Jul, 2026
Opening Date11 Jul, 2026
Cost
Document Cost1000.00
EMD40000.00
Estimated Cost2000000.00
Location
CityBaramulla
StateJammu and Kashmir

Register to see full details

BOQ Items
#ItemQtyUnits
1Complete Job of Retubing of Generator Hot Air coolers/heat exchangers of the hydro generators by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube length of 1.29 m 8.000No's
2Complete Job of Retubing of Turbine Guide bearings coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube length of 2.06 m 2.000No's
3Complete Job of Retubing of Transformer coolers/heat exchangers of 14 MVA Generator Transformers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube length of 1.29 m 4.000No's
4Complete Job of Retubing of Thrust Bearing coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube of varied length 1.12 m to 0.5 m 6.000No's
5Complete Job of Retubing of Upper Guide bearing (UGB)coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube of length 0.99 m and 0.8 m 6.000No's
10th Jul, 2026

5 Days Left

WhatsApp