Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4558120 |
|---|---|
| Organisation Name | Jammu And Kashmir State Power Development Corporation |
| Tender Brief | Corrigendum : Re Tubing Of Damaged Coolers (heat Exchangers) At 3into35 Mw Ljhp Power House Baramulla |
| Last Date For Submission | 10th Jul, 2026 |
| Opening Date | 11 Jul, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 40000.00 |
| Estimated Cost | 2000000.00 |
| City | Baramulla |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Complete Job of Retubing of Generator Hot Air coolers/heat exchangers of the hydro generators by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube length of 1.29 m | 8.000 | No's |
| 2 | Complete Job of Retubing of Turbine Guide bearings coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube length of 2.06 m | 2.000 | No's |
| 3 | Complete Job of Retubing of Transformer coolers/heat exchangers of 14 MVA Generator Transformers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube length of 1.29 m | 4.000 | No's |
| 4 | Complete Job of Retubing of Thrust Bearing coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition of Cu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube of varied length 1.12 m to 0.5 m | 6.000 | No's |
| 5 | Complete Job of Retubing of Upper Guide bearing (UGB)coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 70/30 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power house Tube OD of 19mm Tube of length 0.99 m and 0.8 m | 6.000 | No's |