Tendering Authority: Military Engineer Services
Tender ID4963460
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Testing Repair /maint Of Earthing Of E/m Installations At Afs Amla
Last Date For Submission12th Aug, 2026
Opening Date14 Aug, 2026
Cost
Document Cost500.00
EMD22000.00
Estimated Cost1100000.00
Location
CityBetul
StateMadhya Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Taking down old defective copper conductor strip/wire of any size from wall/foor and making good to the disturbed surfaces to match the existing surface complete all as specified and directed.50RM
2Taking down old defective conductor strips of any type/description (i.e. GI, Aluminium & copper strip) from wall/ roof and making good to the disturbed surfaces to match the existing surface complete all as specified and directed.250RM
3Labour charges to carry out earthing resistance test of earth pits of plants/machinery/panels of E/M installation with well calibrated suitable earth resistance tester after opening the test points and recording the result in presence of MES representative complete all as per IS:3043 of 1966. NOTE: (i) The result shall be recorded in the result sheet and on pit marker and as directed. (ii) Recording the test result of each earthing shall be done on quaterly basis and the test result shall be submitted to the AGE E/M Office quarterly. (iii) It shall be ensured by the Contractor of earth resistance meter shall be well calibrated.3000Per point
4Supply & fix in repair Junction box IP 65 with plain walls of size 167mm x 125mm x82mm made up of Polystyrene having shutter and lifting knob with provision of earth strip entry glands fixed to walls or pole with nuts, bolts, washers and testing complete all as specified and directed.15Each
5M&L for maintenance free grounding solution earthing in replacement of old earthing comprising of high tensile low carbon steel rod of 3 meter length & 17.2 mm dia with 250 micron (average) molecularly bonded copper thickness on the outer surface along with earth enhancing back-fill compound strictly be a carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr, Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction, back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground, back fill compound shall not be mixed with any soil while pouring in the bore hole. The earth electrode should finally be housed in a heavy duty readymade type PVC chamber with future access cover. Make: JEF Technology/ Excel Fibro tech / Trupower solution 25Each