| 1 | ELECTRO-CHLORINATION SYSTEM FOR GETCO ESR STORAGE CAPCITY 1.6 ML & PER DAY WATER SUPPLY 15 MLDSupply, Installation, Testing and Commissioning of Electro-chlorination system, chlorine generation capacity of min. 4000 grams per batch (8 hours cycle),min. 3 nos. numbers of higher Electro Chlorination Systems shall be provided to meet the total chlorine demand,min. dose 2 PPM, Electro Chlorinator unit including FRP Chlorination Tank with lid, Titanium Grade-2 electrodes with MMO coating, DC power supply system, control panel with inbuilt transformer, ammeter, MCB and all internal wiring, along with suitable rating and head Diaphragm type Dosing Pump and 1000 liters capacity storage tank (LLDPE). interconnecting piping, valves, insulated DC cables, and mounting arrangements. The scope also includes providing and laying of power and signal cables of required length between Electro Chlorinator unit, control panel and PLC/HMI panel, complete with double compression weatherproof Ni-Brass cable glands, termination at both instrument and panel ends. | 1.000 | LOT |
| 2 | ELECTRO-CHLORINATION SYSTEM FOR DIAMOND SQUARE ESR STORAGE CAPCITY 1.5 ML & PER DAY WATER SUPPLY 15 MLDSupply, Installation, Testing and Commissioning of Electro-chlorination system, chlorine generation capacity of min. 4000 grams per batch (8 hours cycle),min. 3 nos. numbers of higher Electro Chlorination Systems shall be provided to meet the total chlorine demand,Electro Chlorinator unit including FRP Chlorination Tank with lid, Titanium Grade-2 electrodes with MMO coating, DC power supply system, control panel with inbuilt transformer, ammeter, MCB and all internal wiring, along with suitable rating and head Diaphragm type Dosing Pump and 1000 liters capacity storage tank (LLDPE). interconnecting piping, valves, insulated DC cables, and mounting arrangements. The scope also includes providing and laying of power and signal cables of required length between Electro Chlorinator unit, control panel and PLC/HMI panel, complete with double compression weatherproof Ni-Brass cable glands, termination at both instrument and panel ends. | 1.000 | LOT |
| 3 | ELECTRO-CHLORINATION SYSTEM FOR VARDHAMAN ESR STORAGE CAPCITY 1.5 ML & PER DAY WATER SUPPLY 25 MLDSupply, Installation, Testing and Commissioning of Electro-chlorination system, chlorine generation capacity of min. 4000 grams per batch (8 hours cycle),min. 5 nos. numbers of higher Electro Chlorination Systems shall be provided to meet the total chlorine demand,min. dose 2 PPM,Electro Chlorinator unit including FRP Chlorination Tank with lid, Titanium Grade-2 electrodes with MMO coating, DC power supply system, control panel with inbuilt transformer, ammeter, MCB and all internal wiring, along with suitable rating and head Diaphragm type Dosing Pump and 1000 liters capacity storage tank (LLDPE). interconnecting piping, valves, insulated DC cables, and mounting arrangements. The scope also includes providing and laying of power and signal cables of required length between Electro Chlorinator unit, control panel and PLC/HMI panel, complete with double compression weatherproof Ni-Brass cable glands, termination at both instrument and panel ends. | 1.000 | LOT |
| 4 | ELECTRO-CHLORINATION SYSTEM FOR PRABHUDAS ESR STORAGE CAPCITY 1.3 ML & PER DAY WATER SUPPLY 12 MLDSupply, Installation, Testing and Commissioning of Electro-chlorination system, chlorine generation capacity of min. 4000 grams per batch (8 hours cycle),min. 3 nos. numbers of higher Electro Chlorination Systems shall be provided to meet the total chlorine demand,min. dose 2 PPM,Electro Chlorinator unit including FRP Chlorination Tank with lid, Titanium Grade-2 electrodes with MMO coating, DC power supply system, control panel with inbuilt transformer, ammeter, MCB and all internal wiring, along with suitable rating and head Diaphragm type Dosing Pump and 1000 liters capacity storage tank (LLDPE). interconnecting piping, valves, insulated DC cables, and mounting arrangements. The scope also includes providing and laying of power and signal cables of required length between Electro Chlorinator unit, control panel and PLC/HMI panel, complete with double compression weatherproof Ni-Brass cable glands, termination at both instrument and panel ends. | 1.000 | LOT |
| 5 | ELECTRO-CHLORINATION SYSTEM FOR KUMBHARWAD ESR STORAGE CAPCITY 1.5 ML & PER DAY WATER SUPPLY 10 MLDSupply, Installation, Testing and Commissioning of Electro-chlorination system, chlorine generation capacity of min. 4000 grams per batch (8 hours cycle),min. 2 nos. numbers of higher Electro Chlorination Systems shall be provided to meet the total chlorine demand,min. dose 2 PPM,Electro Chlorinator unit including FRP Chlorination Tank with lid, Titanium Grade-2 electrodes with MMO coating, DC power supply system, control panel with inbuilt transformer, ammeter, MCB and all internal wiring, along with suitable rating and head Diaphragm type Dosing Pump and 1000 liters capacity storage tank (LLDPE). interconnecting piping, valves, insulated DC cables, and mounting arrangements. The scope also includes providing and laying of power and signal cables of required length between Electro Chlorinator unit, control panel and PLC/HMI panel, complete with double compression weatherproof Ni-Brass cable glands, termination at both instrument and panel ends. | 1.000 | LOT |