Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Urban Improvement Trust
Tender ID3875405
Organisation NameUrban Improvement Trust
Tender BriefCorrigendum : Sukhadiya Stadium Ke Cricket Ground Me Ratri Meacho Ke Liya Flood Light Lagane Ka Karya
Last Date For Submission21st Apr, 2026
Opening Date23 Apr, 2026
Cost
Document Cost1000.00
EMD198560.00
Estimated Cost9928000.00
Location
CityBhilwara
StateRajasthan

Register to see full details

BOQ Items
#ItemQtyUnits
1SITC of 30 meter Stadium mast in three sections including headframe suitable for wind speed 50 m/sec. and suitable to install 28 nos. of LED luminaries in asymmetrical arrangement Minimum Lux level of 500 Lumens on Cricket field accessories including ladder ,rings for protection around the ladder and other manufactured items & necessary hardware s including foundation aviation light etc. All the cables from fixtures to the mast on the head frame should be inside the flexible steel conduit pipe , complete in all respect. Specification of the Stadium mast as mentioned below . Make : Philips , Surya , GE .4.00NOS
2Providing & Fixing of IP66 protected high power LED flood light system with pressure die cast housing, toughened glass/IP Lens diffuser with suitable lens cluster for optimum light distribution to achieve beam angle of 30/60 degree, 240 volts AC, 50 Hz, of high power LEDfixture supplied with prewired cable. integrated driver shall be of high efficiency more than 85%. The system level luminaire efficacy >/= 135 lumen / watt with high power LED of CREE / NICHIA / OSRAM / PHILIPS / SEOUL make is to be used. Input Voltage 130V- 270 V AC, Power Factor >0.95, Frequency 50 Hz (+/- 3%), THD < 10%, Colour Temperature 5700 K, CRI > 70, Ingress Protection IP66, Impact Resistance IK 05, Surge Protection Minimum 5 KV internal and 10 KV external. Life expectancy equal to or more than 50000 burning hours withminimum 70% lumen maintenance. Mark / Brand to be engraved / embossed on die cast housing. The manufacture should have NABL accredited lab with photo metric testing facility. HIGH POWER LED FLOOD LIGHT 500 W, Make Surya, Philips GE112.00NOS
3Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
43 x 2.5 sq.mm3650.00Mtr.
5Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
21st Apr, 2026

11 Days Left

WhatsApp