Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4949385
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Comprehensive Maint Of Certain E/m Works At Domestic Area At Bhisiana Under Ge (af) Bhisiana
Last Date For Submission11th Aug, 2026
Opening Date13 Aug, 2026
Cost
Document Cost500.00
EMD50000.00
Estimated Cost2500000.00
Location
CityBhisiana
StatePunjab

Register to see full details

BOQ Items
#ItemQtyUnits
1Supplying and drawing in replacement 1.5 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to light points, fan points, exhaust fan points, socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge. Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only.1600.00RM
2Supplying and drawing in replacement 2.5 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/ casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to power point socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge. Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only.800.00RM
3Supplying and drawing in replacement 4 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/ casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to geyser point, AC point, power point socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge. Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only.300.00RM
4Supplying and drawing in replacement 6 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/ casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to geyser point, AC point, power point socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge. Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only.100.00RM
5Supply and fixing in replacement of pressed steel powder-coated sunken terminal box of size 100 mm 100 mm, minimum 50 mm deep, suitable for mounting non-modular switches, socket outlets, fan regulators and other wiring accessories, complete with 3 mm thick plastic laminated sheet cover duly cut to accommodate the respective accessories. The item shall include dismantling of the existing terminal box, fixing the new box in position, making good the disturbed wall surface with cement mortar (1:3) to match the existing finish, and providing all necessary fixing materials, steel screws, rawl plugs and other accessories required for proper installation, complete in all respects as specified and directed by the Engineer-in-Charge. Note: The rate shall be deemed to include refixing of existing serviceable switches, socket outlets, fan regulators and other accessories. However, if any switch, socket outlet, fan regulator or other accessory is found unserviceable and requires replacement with a new one, the same shall be measured and paid for separately under the respective BOQ item.3.00Each Job
11th Aug, 2026

16 Days Left