Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID3945175
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Special Repair To Ber Ac Plant Of Ot And Cold Cabinets In Mortuary At Af Stn Halwara Under Ge (af) Halwara
Last Date For Submission27th Apr, 2026
Opening Date29 Apr, 2026
Cost
Document Cost1000.00
EMD139900.00
Estimated Cost7660000.00
Location
CityBhisiana
StatePunjab

Register to see full details

BOQ Items
#ItemQtyUnits
1Dismantling taking down old unserviceable Chiller plant 21TR of 3 Nos plants complete including motor, pump, pipe line, Valves , ducts , diffusers and dampers and depositing it in MES store and making good the disturbed portion complete all as specified and directed by Engr in Charge Note: Rate quoted is for 3 nos of chiller plant.1Each Job
2Design ,Supply , install , commissioning and testing of Water Cooled Scroll Chillers, with multi compressors, comprising of Semi - Hermetic/Hermetic/ Open Type Compress-ors, DX Evaporator, Shell and Tube Condenser,suitable expansion device,suitable for operation on R - 22 /R - 407 C/R 410a for existing rooms which were airconditioned at Site of nominal capacity not less than 21 TR (each) with circulation rate of 610 LPM(160 GPM)(nominal) or as recommend by OEM each comprising of the following complete as per specification and as reqd. Compressor automatic capacity control, safety switches, forced feed lubrication insulated chiller, ,water flow switch , vibration isolators, integral refrigerant piping and wiring , automatic and safety controls mounted in central console panel and all mounted on a steel frame (complete as per specifications). shall be suitable for 415volt 50Hz cycles. 3 phase AC supply. including all required accessories as per specifications. Note :(i) Contractor has to submit ,get the design of Chiller plant approved from accepting officer before incorporating the same on ground. (ii) The design condition of the plant should be able to meet the desired temeprature of 22 C+2 C , with RH of 55% +5% as per the weather conditions of Halwara during Summer, Monsoon & Winter. (iii)The plant is to be designed such that to meet the desired temperature with 2 units run at a time and 01 will be standby. ( 02 working & 01 Standby). (iv) The Air changes is to be calculted for Hospital rooms as applicable per Indian Standards or as appliacble Refrigerant - R-134A/ R - 407 C/R 410A Evaporator fouling factor -0.0001 (British Units) Condenser fouling factor-0.00025 (British Units) ( 2 units working & 01 standby) 3Each Job
3Design ,Supply, installation, testing and commissioning of electrical Hot water Generator of vertical construction equipped with sufficient number of flanges and electric emersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fiberglass with 0.6mm Aluminium cladding as per specifications.The hot water generator shall be equipped with all automatic and safety controls such as manual reset, high temperature water cutout, step controller, on/off switch, pilot light,low water cut off and other controls as per manufacturers recommendations.All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts, 50 Hz, 3phase power supply.The entire hot water generator shall be factory assembled and tested including 02 Nos Hot water generator pump of suitable capacity. Note :(i) Contractor has to submit ,get the design of Hot water generator approved from accepting officer before incorporating the same on ground. (ii) The design condition of the plant should be able top meet the desired temeprature of 22 C+2 C , with RH of 55% +5 % as per the weather conditions of Halwara during Summer, Monsoon & Winter.1Each Job
4Design,Supply, installation,commissioning and testing of induced drafttop discharge counterflow type FRP Cooling Tower(Rectangular/Roundbottle shape) with FRP body and base, water spray headers, coolingtower fills, fan withmotor, supporting baseframes, as permanufacturer's standard instructions suitable for Chiller plant designed as mentioned in item ser No 2 with the cololoing tower capacity not less than 50 TR. The cooling tower should have the following features FRP Water basin, PVC Filling with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor with high efficiency class , suction screen, make-up quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior, Range: 4.2 Deg. C/ 7.5 Deg. F Condenser water inlet/outlet temp-90-97 Deg F Wet Bulb Approach: 2.78 Deg. C/ 5 Deg. F1Each Job
5Design ,Supplying, erection, testing and commissioning of chilled water pump set for chilled water suitable for plant as mentioned in Item ser No 2 above. The pump to be disigned with 2 working and 01 standby concept. The pumpset to have followiung specifications TEFC squirrel cage induction motor with class 'F' insulations & efficiency class EFF1 4pole synchronous speed , operating on 415 volts ,3 phase , 50 Hz A.C .suply.Min. pump efficiency at duty conditions shall not be less than 75%3Each Job