| Tender Brief | Corrigendum : Repair/maint Of Lt Panel, Lt Distributer, Lt Feeder Pillar Box, Apfc Panels And Caliberation Of Panels And Connected Works At Ge Dronachal |
| Last Date For Submission | 19th May, 2026 |
| Opening Date | 21 May, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 80000.00 |
| Estimated Cost | 4000000.00 |
| City | Bhopal |
|---|---|
| State | Madhya Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for Each 3 3 phase 4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made sheet and MS ang angle iron 3.15 mm thick CRCA out of 3.1 sectiom 40X40X6mm frame with front and back openable double door system with locking anagement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yellow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, fremuled for proper indication, Panel shall be grouted in PCC foundation complete all as specified and directed with following accessories- | 1.00 | Each Job |
| 2 | INCOMING- (a) MCCB 200 Amps microprocessor released 415 Volts. 25 KA, 4 pole-01 No. (b) MCCB 100 Amps microprocessor released 4 pole 415 Volts, 25 KA-2Nos & MCCB 63 Amps with microprocessor based 4 pole 415 Volts, 25 KA -04 Nos (c) Digital type Volt meter 0-500 Voltssquare type with selector switch-01 No. (d) Digital type Ammeter 0-400 Amps square type with selector switch-01 No. (e) Wiring complete with copper wire of suitable size (f) indicator lamp LED type, set of three marked red, yellow & blue-01 Set (g) Cable glands brass of suitable size for cable. Note:- Approval of GE must be obtained for Panel design/drawing and CPRI approval of manufacturer before placing order. | ||
| 3 | Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for Each 3 3 phase 4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made sheet and MS ang angle iron 3.15 mm thick CRCA out of 3.1 sectiom 40X40X6mm frame with front and back openable double door system with locking anagement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yellow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, fremuled for proper indication, Panel shall be grouted in PCC foundation complete all as specified and directed with following accessories- | 1.00 | Each Job |
| 4 | INCOMING- (a) MCCB 250 Amps microprocessor released 415 Volts. 25 KA, 4 pole-01 No. OUT GOING (a) MCCB 63 Amps microprocessor released 4 pole 415 Volts, 25 KA- 08Nos & MCB SPN 40 Amps with microprocessor based 3 pole 240 Volts, 10 KA -04 Nos (b) Digital type Volt meter 0-500 Voltssquare type with selector switch-01 No. (c) Digital type Ammeter 0-400 Amps square type with selector switch-01 No. (d) Wiring complete with copper wire of suitable size (e) indicator lamp LED type, set of three marked red, yellow & blue-01 Set (f) Cable glands brass of suitable size for cable. Note:- Approval of GE must be obtained for Panel design/drawing and CPRI approval of manufacturer before placing order | ||
| 5 | MSL cutting PCC/floor/road and taking out cable and making good, with material as per existing after laying of pipe for cable protection including Cement concrete work in pavement/ hard-standing of frexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less all as specified and directed size of trench not more than 0.30 x 0.30 cm. | 2.50 | cum |