Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3976958 |
|---|---|
| Organisation Name | Works Department |
| Tender Brief | Corrigendum : Fire Safety Measures At Svppgip Sishubhawan, Cuttack Such As Supply, Installation, Testing and Commissioning Of Smoke Exhaust System Of Nicu, Picu And Different Wards With Make Up Air System |
| Last Date For Submission | 30th Apr, 2026 |
| Opening Date | 30 Apr, 2026 |
| Document Cost | 10000.00 |
|---|---|
| EMD | 142410.00 |
| Estimated Cost | 14240980.00 |
| City | Bhubaneswar |
|---|---|
| State | Odisha |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | SITC of Tube-axial Smoke exhaust fan complete with cast aluminium impeller and all standard accessories like drive motor suitable for handling hot gas of temperature 350 Deg C for 2 hours, motorized isolating damper at fan inlet, rain protection cowl with bird screen/back draft damper at fan discharge, supports and supporting structures, for 4 point clamping with Vibration spring isolater and Motorized damper shall be rated for 240 V, 50 Hz, 1 Ph., AC supply.The Motor shall be of TEFC, IP-55 protection, Class 'H' insulation, motor shall be of IE-3 efficiency, suitable for 3 Phase, 415volts, 50hz power supply.Fan Shall be Oprating in Dual Mode in Normal Ventilation & another in Fire Mode Fan Make - Airflow /Krugger/Nikotra Capacity of each Fan : 12000 CFM IN FIRE MODE & 6000 CFM IN VENTILATION MODE Static Pressure : 25 mmWG | 11.00 | Nos |
| 2 | Area - Lift Corridoor & Its Adjoing Common Passage area . 15000 CFM IN FIRE , Location - AHU Room | 5.00 | Nos |
| 3 | 8000 CFM IN FIRE , LOCATTION - AHU ROOM | 3.00 | Nos |
| 4 | SITC of Wall mounted type Fresh air Fan Filter Unit consists of Tube Axial flow fan with High Efficiency Drive Motor (conforming to IS-12615) TEFC with Inlet Louver, supports and supporting structures, vibration isolators, nuts and bolts and short ducting with SA register (if required). Motorized damper shall be rated for 240 V, 50 Hz, 1 Ph., AC supply and The Motor shall be of TEFC, IP-55 protection, Class 'H' insulation, motor shall be of IE-3 efficiency, suitable for 3 Phase, 415volts, 50hz power supply.Fan Shall be Oprating in Dual Mode in Normal Ventilation & another in Fire Mode Capacity of each Fan : 10000 CFM IN FIRE MODE & 5000 CFM IN NORMAL VENTILATION MODE Static Pressure : 15 mmWG | 11.00 | Nos |
| 5 | Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, wall mounted control panels including anchoring into the wall, wiring and earthing terminating into MPCB in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BMS. All starters shall be provided with potential free Contact for Connections to Building Automation System. Over-load relay, suitable for motor duty and able to withstand fault level of suitable KA rating. single phase preventer (Electronics type) as per the ratings given below. Terminal block for power distribution. Power Contactor. Phase indicating lights and indicating light for ON/OFF/TRIP status phase sequence relay shall also be provided. Time delay relay for delayed automatic restart of motor (0-180 sec). Integration with fire alarm detection system and fire damper for starting / stopping the fan (in case of fire) / Power supply for damper control panel. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. The number of control panels shall be as follows. Make (Swithcgear) - ( MCCB : Make-Legrand-(DPX3)/Schneider-(CVS)/Siemens-(3VA) /ABB (Tmax), MCB : Make-Legrand-(DX3)/Schneider-(Acti9)/Siemens-(betagard)/ ABB (SB200) 16/25/32/63A 4P MPCB with 5/10/15 HP Three phase VFD with bypass star delta/DOL starter with overload relay and single phase preventer . Each of these compartment shall contain indicating lamp with ON/ OFF/ TRIP status for fan sections/axial fans. | 30.00 | Nos. |
9 Days Left