Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4429812
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Comprehensive Maint And Repairs To Ht 33/11 Kv Mrs And Other Substations, Ht Panels, Ht Vcb, Transformers Connected Infrastructure At Domestic Area Under Ge (af) Bidar
Last Date For Submission24th Jun, 2026
Opening Date27 Jun, 2026
Cost
Document Cost500.00
EMD68000.00
Estimated Cost3400000.00
Location
CityBidar
StateKarnataka

Register to see full details

BOQ Items
#ItemQtyUnits
1Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 3 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period for insulation resistance testing, CRM testing, 3 pole timing testing with transportation under AMC and duly carring out servicing,overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom) of any technical specification of 33 KV grade VCB current rating 400/630/800/1250 Amps (incoming/out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side in all respects after complete servicing with facilitated operating features, and cleaning,overhauling,relay calibration and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed.3.00Each Job
2Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 2 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period duly carring out servicing,overhauling, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom /Scheneider/L&T) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side operations in all respects and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed.26.00Each Job
3Note for 1 & 2: (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate. (ii) Servicing shall be got carried out thorugh a approved agency of any state/Central govt CEI (chief electrical Inspectorate) (iii) Engineer shall be consider repair/servicing duly reference taken from OEM drawings and tech specifications and service engineer will submit a service report and calibration certificate for each VCB. (iv) Any minor item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included in the quoted rates. (v) Failing attend the lodged complaint of any mode within 24 Hours will imposed penalty of Rs 1000/fault for each day cumulatively and same shall be deducted from his dues.
4M&L for top up/replacement of transformer oil with new transformer oil in the existing transformer in yard 11/0.433 or 33/11 KV upto achieve the required level duly testing the old oil after filtration by the centrifuging machine measured under relevent items, if the oil not obtain deserved insulation levels replace the complete oil all as specified and as directed Make :- Power Oil/ Transol/ GET700.00Ltr
5M&L for filteration, centrifuging and testing of PowerDist transformer oil by using centrifuging/ filteration machine for installed transformer, 33/11/0.433 KV at various sub station in order to achieve the desired dielectric strength of transformer oil as per relevent IS-1981 complete all as specified and as directed5000.00Ltr
24th Jun, 2026

6 Days Left

WhatsApp