| 1 | Rajiasar PS-I
A). Pump and Bowl Assemblies:- | | |
| 2 | S I T C of Vertical wet well type pump complete with Bowl assembely,column pipe, delivery Tee, motor stool, shafts, bearings, bearing housing,pressure gauges, Bearing temperature gauge, sole plate conforming to IS:1710 & min. efficiency not less than 87% at Rated discharge and StaticHead complete with all accessories as per specification & approved make,carrying of third party inspection, transporation up to site, loading,unloading, erection, commissioning, Testing , Three month trial run & one year defect liability. For Additional technical parameters of product / work refer Annexure 'A' attached with this BSR2.81 cumec/100 cusec (17 to 20 meter) | 1.00 | Each |
| 3 | SITC of Complete Discharge bowl assembly conforming to IS: 1710 &min. efficiency not less than 87% having Rated discharge capacity andtotal static head complete with all accessories as per specification &approved make , including work of dismantaling of existing pump ,providing and replacement of Top shaft, intermediate shaft, various shaftsleeves, Rubber bearings and bushes, Muff couplers with thrust halfs, keys,High tensile Nut bolts for complete pump, and carrying of third partyinspection, transporation up to site, loading, unloading, erection,commissioning Testing ,Three month trial run & one year defect liability.For Additional technical 100 CS (17 to 20 meter) | 1.00 | Each |
| 4 | S I T C of Vertical wet well type pump complete with Bowl assembly, column pipe, delivery Tee, motor stool, shafts, bearings, bearing housing, pressure gauges, Bearing temperature gauge, sole plate conforming to IS: 1710 & min. efficiency not less than 87% at Rated discharge and Static Head complete with all accessories as per specification & approved make, carrying of third party inspection, transportation up to site, loading, unloading, erection, commissioning, Testing , Three month trial run & one year defect liability. For Additional technical parameters of product / work refer Annexure 'A' attached with this BSR
For static head 17 meter to 20 meter
Design discharge 2.12/2.15 cumec | 1.00 | Each |
| 5 | SITC of Complete Discharge bowl assembly conforming to IS: 1710 & min. efficiency not less than 87% having Rated discharge capacity and total static head complete with all accessories as per specification & approved make , including work of dismantling of existing pump , providing and replacement of Top shaft, intermediate shaft, various shaft sleeves, Rubber bearings and bushes, Muff couplers with thrust halfs, keys, High tensile Nut bolts for complete pump, and carrying of third party inspection, transportation up to site, loading, unloading, erection, commissioning Testing ,Three month trial run & one year defect liability. For Additional technical parameters of product / work refer Annexure 'A' attached with this BSR
For static head 17 meter to 20 meter
Design discharge 2.12/2.15 cumec | 2.00 | Each |