| Tender Brief | Corrigendum : Maintenance Of Electrical Installation In Non-residential Building At Chandigarh (amc Of Laser Based Fire Detection System Installed In Judicial Archive Building, Plot No. 841, Industrial Area, Phase Ii, Chandigarh). |
| Last Date For Submission | 20th Jul, 2026 |
| Opening Date | 20 Jul, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 2070.00 |
| Estimated Cost | 103398.00 |
| City | Chandigarh |
|---|---|
| State | Chandigarh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Providing Annual Comprehensive Maintenance of Short wave length laser-Based Smoke Detection System with 4 pipe inlets, 3.5" LCD touch screen display, 2000 m2 coverage including false floor and false ceiling; built in 4 alarm levels; High efficiency aspirator; Clean air barrier optics protection; dual stage filter with built in memory; 7 Nos. of inbuilt potential free relay outputs; supports linear pipe length of 70m per pipe (total 280m) or branched pipe up to 100m per pipe; supports 40 Nos. of Class A sampling points, Auto Learn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP & Two Core Wire network connectivity built in for central monitoring & monitoring through Centralized software. Under the AMC the firm shall provide maintenance service of the system. The service must be carried out weekly and the complaint call must be attended by the firm in addition to the general maintenance within two hours from the time of such calls.(Please refer DNIT for complete specification of item no.1) | 1 | Each job per year |
| 2 | DSR item No.28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. | 2 | Each |
| 3 | DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | ||
| 4 | 2 x 1.5 sq.mm | 50 | PM |
| 5 | Supply, erection, testing & commissioning of batteries of the following capacities after dismantling the old / defective batteries from the site. The job includes the cost of making connection of new battery with suitable rating copper wire, thimbles & any other petty material required to complete the job to the entire satisfaction of the Engineer-in-charge. The batteries should be of Exide / Amaron / Tata Green / Panasonic make only. |