Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4600992 |
|---|---|
| Organisation Name | Chandigarh Administration |
| Tender Brief | Corrigendum : Repair/replacement Of Faulty Underground Lt Cable For 3 Nos. High Mast Lighting Poles In The Premises Of Ctu Workshop, Depot-iii Sector-25, U.t., Chandigarh. |
| Last Date For Submission | 24th Jun, 2026 |
| Opening Date | 24 Jun, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 7000.00 |
| Estimated Cost | 346764.00 |
| City | Chandigarh |
|---|---|
| State | Chandigarh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | DSR ITEM No.2.4Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required. | ||
| 2 | 4 way (4 + 12), Double door | 1.00 | Each |
| 3 | DSR Item No. 2.10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | ||
| 4 | Single pole | 12.00 | Each |
| 5 | Triple pole and neutral | 1.00 | Each |
4 Days Left