Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Postgraduate Institute Of Medical And Education And Research
Tender ID4432582
Organisation NamePostgraduate Institute Of Medical And Education And Research
Tender BriefCorrigendum : Replacement Of Existing Doors With Fire Resistant Doors In The Ahu Rooms At Various Locations Including Entry Of Ent Ward And Icu Area At Level A 1 And A 2, Nehru Hospital Extension Block, Pgimer, Chandigarh
Last Date For Submission22nd Jun, 2026
Opening Date23 Jun, 2026
Cost
Document Cost0.00
EMD71940.00
Estimated Cost3597000.00
Location
CityChandigarh
StateChandigarh

Register to see full details

BOQ Items
#ItemQtyUnits
1Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)12.760Cum
2Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper60.000Each
3Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m ) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.6.050Sqm
4Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick85.050Sqm
5Neat cement punning.85.050Sqm
22nd Jun, 2026

10 Days Left

WhatsApp