| Tender ID | 4836871 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Cwe/chm(u)-33/2026-27 Preventive Maintenance Of Ac Plant In Manekshaw Auditorium Under Age E/m Ii Of Ge(u) Chandimandir |
| Last Date For Submission | 27th Jul, 2026 |
| Opening Date | 29 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 19500.00 |
| Estimated Cost | 975000.00 |
| City | Chandimandir |
|---|---|
| State | Haryana |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Organizing visit of skilled technician/ Engineer of OEM (which is Blue Star) of central AC Plant of capacity 2 x 56 TR (Chilled water and strip heater type) air cooled type installed at Manekshaw Auditorium for the followings :- (i) Depute a skilled technician/ Engineer for two working days except Sunday/ Holidays. (ii) Checking, Testing and providing consultancy for necessary repair to be carried out and providing necessary testing report of each Central type AC plant unit. (iii) Providing consultancy for repairing maintenance schedule for the smooth working of all equipments. (iv) The entire equipments will be serviced in presence of skilled technician. | 1.00 | Per Visit |
| 2 | Note: (a) Necessary repairs and parts to be replaced will be paid separately under respective items. (b) Contractor will provide the uniforms for technicians. (c) Contractor will provide necessary documents from the OEM in respect of visit to be carried out as required by engineer-in-charge. (d) First such inspection and servicing shall be carried out within 21 days from the date of commencement of work given in work order No 01. (e) Minor spares such as nuts, bolts, washers, aluminum lugs, grease or any minor spare part required for satisfactory operation of AC plant, other than mentioned in this CA here-in-after are deemed to be included in unit rate quoted by the contractor. (f) If Contractor fails to repair/ replace any faulty items within 24 Hours after entry of fault in log sheet, a panel recovery of Rs. 1000/- per day after 24 hours shall be recovered from next RAR from the contractor without any formal communication besides the recovery of penalty. | ||
| 3 | The details of plant equipments are as follows:- (i) Multi stage reciprocating compressor: Model. XACYS2060R2. Make: Blue Star (Capacity 18 TR each) (Three Nos in each set) -02 Set (ii) Electrical control panel (LT) 440 volts, 680 Amps - 02 Nos. (iii) Condenser and chiller of shell and tube type - 02 Nos (iv) AHU blower motor of capacity 11 KW - 02 Nos. (v) Chilled water pumping set of 7.5 HP, 3 phase, 440 volts - 03 Nos. (vi) Paharpur induced draft cooling tower, 204 Ton, with 15 HP - 01 No wheather proof, gear driven electrical motor. (vii) All other connected items of the plants/ equipments/ machines mentioned in respects of sub paras (i) to (vi) above. Contd.. | ||
| 4 | Contd.. (viii) Air handling unit, blower, evaporating coil and other sections of humidification arrangements, electrical panels etc and all other connected items - 06 Nos. (ix) Water softening unit with monoblock pump 2 HP- 01 No. Notes :- Following checks and duties shall also be carried out under this item:- (a) Checking the proper functioning of all Air Conditioning plants 2X 56 TR and AHU's. Make: Blue Star. | ||
| 5 | Supply and charging of Gas R-407C suitable for 2 x 56 TR chiller plant after detecting and rectification of any leakage in system by using CO2 gas and flushing the complete system with Nitrogen gas as required complete all as specified and directed by Engr-in-Charge. Note : (a) Gas to be brought by contractor at site from authorised dealer in company sealed cylinder. (b) The unit rate inserted shall deemed to be included the cost of CO2 and Nitrogen gas to be used for leakage test and flushing and pressure test prior to charging the gas in plant as required. | 60.00 | Kilogram |