Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4948560 |
|---|---|
| Organisation Name | HLL Biotech Limited |
| Tender Brief | Corrigendum : Design, Supply, Installation, Testing And Commissioning Of Chemical Sanitizable Reverse Osmosis (csro) System At Existing Water Pre-treatment Plant At Ivc Facility At Hll Biotech Limited, Chengalpattu, Tamil Nadu |
| Last Date For Submission | 28th Jul, 2026 |
| Opening Date | 29 Jul, 2026 |
| Document Cost | 1770.00 |
|---|---|
| EMD | 164700.00 |
| Estimated Cost | 6587000.00 |
| City | Chengalpattu |
|---|---|
| State | Tamil Nadu |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Design, Supply, installation and testing of automated CSRO Plant with the following components but not limited to : | ||
| 2 | Product output Flow: Not less than 15 cubic meter per hour Current Inlet TDS of water : 570 PPM Skid MOC: SS 304 Skid Mounted CSRO System RO Feed Pump - 02 set. (1 Working + 1 Stand by )/ Make: Grundfos / MOC: SS304 Highpressure Pump - 02 set . (1 Working + 1Stand by) / Make: Grundfos / MOC: SS304 5 Micron filter - OEM approved Chemically Sanitisable RO Membranes: Make: DOW - Dupont (Filmtec) Acid/Base Dosing System with pump , tank with level indicators - 01 Set Antisclant Dosing System with pump , tank with level indicators - 01 Set SMBS Dosing System with pump , tank with level indicators - 01 Set Dosing pump: Make: Prominent Dosing Tank: MOC: HDPE, Make : Sintex Inter connecting pipings of RO & Filter Housings: - SS316L (For complete pipings / interconnections in the RO skid) Inter connecting pipings that to be in UPVC, Make : Astral RO permeate and RO reject line can be UPVC. UPVC piping upto RO Feed pump inlet also to be considered. HPS / LPS with gauge - 01 Set Make: Baumer/Warree ROTO Meters (Product Flow, Rejct Flow, Recirculation Flow) - Each Set 1 nos Digital Flow meter at RO Outlet - 1 No./ Make: Krohne Conductivity Sensor cum Transmitter (Dump valve and line for high conductivity detection) / Make: Emerson pH Analyser - Make: Emerson, ORP Analyser - Make: Emerson, ORP Dump Valve / Make: Liestung / Mascon Necessary Valves and fittings with sampling point provision to be considred. All pnumatic tubes make: Festo. | 1 | SET |
| 3 | Note: The below points to be taken into consideration for the above metioned points Inter connecting pipings of /RO & Filter Housings: - SS316L for complete pipings / interconnections in the RO skid Inter connecting pipings of UPVC for RO permeate and RO reject line shall be considered. Piping to be considered in UPVC are : 1. Existing softener outlet to RO feed tank (2 Nos) , 2. Inter connections of both RO feed tanks, 3. Air vents and Drains, 4. Suction line to RO feed pumps from tanks, 5. RO reject line to reject tanks (2 Nos) and its interconnections, any other lines as per site requirements etc. 6. Any other inter conncetion lines which are not considered but has to be there according to site requirements. *Civil core cuttings for any for the above pipings shall also be under vendor scope ** Piping supports (MS - with painting) for all inter conncting lines to be considered as per site conditions. Instrumentation: 1. Necessary Valves and fittings with sampling point provision to be considred. 2. Vendor should also consider any other components/ items which seems mandatory for operations of CSRO which are not listed above according to site conditions. 3. SS piping to be considered from existing compressed air point to CSRO. | ||
| 4 | RO Feed Water Storage Tank with Level Indicator and all other fittings and drain with valves: Capacity: 15 KL / Make: Sintex | 2 | Nos |
| 5 | Reject Water Storage Tank with Level Indicator and all other fittings and drain with valves: Capacity: 10 KL / Make: Sintex | 2 | Nos |