| Tender ID | 4468833 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repairs And Maintenance Of Ht Distribution Network Including Repairs To Vcbs Transformers, Ht Ug Cables Etc And Connected Works At Cvrde Avadi |
| Last Date For Submission | 26th Jun, 2026 |
| Opening Date | 01 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 30000.00 |
| Estimated Cost | 1500000.00 |
| City | Chennai |
|---|---|
| State | Tamil Nadu |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Material & Labour for Servicing HT VCB panel cum breaker 1250/800/630A 13.1KA rating Indoor type make of SEIMENS/CROMPTON/SCHINDER after taking proper shut down and disconnecting the cables from panel draw out VCB breakers, earth fault relay, checking alignment of VCB isolating contact, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decarburizing of panel, bus bar section & circuit section including incoming/ outgoing cables, provide necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of worn-out/defective spares like tension springs, torsion springs, nut bolts, washers of suitable size, lingers and de-carbonizing all joints, bus bar, CTs, PTs spout metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance of breaker under the supervision of authorized dealer /representative and reconnecting the panel/breaker in its original position and testing all as specified and directed. Note: - (i) The rate quoted inclusive of all minor spares and consumables etc. required at site. (ii) Spares parts required other than mentioned here-in-after shall be deemed to be included in the quoted rate. | 10.00 | Each Job |
| 2 | Supply and fix in replacement of shunt trip coil 220/110 or 30 Volts DC complete all as specified and directed. | 1.00 | Each |
| 3 | Supply and fix in replacement of closing trip coil 220/110 or 30 Volts DC complete all as specified and directed . | 1.00 | Each |
| 4 | Supply & Fix in repair fuse element 20A-50A at 2/4pole 11KV structure unit complete all as specified and directed | 3.00 | Each |
| 5 | Supply & Fix in repair new vacuum interrupter 800/630A 11KV rating suitable for HT breaker of approved make or Brand complete all as directed and directed by Engr-In-Charge. | 1.00 | Each |