Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 2911225 |
|---|---|
| Organisation Name | Rajasthan Rajya Vidyut Prasaran Nigam Limited |
| Tender Brief | Corrigendum : Supply, Installation And Calibration Of Various Lab Instruments For Measurement Of Various Parameters Of Water And Oil At Chemical Laboratory, Ctpp-o And M, Chhabra |
| Last Date For Submission | 7th Apr, 2026 |
| Opening Date | 08 Apr, 2026 |
| Document Cost | 590.00 |
|---|---|
| EMD | 40940.00 |
| Estimated Cost | 2046000.00 |
| City | Chhabra |
|---|---|
| State | Rajasthan |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Coulometric Karl fisher Automatic titrator (1. Method of Measurement: Coulometric Karl Fischer Titrator for low level (Trace level) moisture. 2. Measuring Range: 10 g to 200mg / 1ppm to 5%. and Measurement Range [ A] : 0 A to 100 A 3. Moisture Range : Instrument is able to measure trace level moisture 4. Resolution : 0.1 g Water 5. Polarisation Voltage : Variably adjustable from 40 220 mV 6. Measurement Accuracy without sensor probe : +/- 0.2 A +/- 1 Digit 7. Drift Compensation: Automatic drift Compensation. 8. End point Indication: Visual Display/ Acoustic Beep. 9. End point Criteria: Drift, stop drift tolerance min & max titration time. 10. Accuracy : < 0.3% 11. Result: Instrument is able to display the moisture content in (mg/kg) /(ppm) / (% H2O) 12. Titration Vessel : Glass vessel 200-250ml 13. No. of Methods : 50 14. Magnetic Stirrer with integrated pump and variable stirrer speed 15. The complete system is hermetically sealed to exclude all possibility of ingress of any external moisture into the system. 16. Stirring speed: 50 ... 1000 U/min 17. Titration Stand: Titration stand to hold the titration vessel in position with Built-in magnetic stirrer. 18. Generator Electrode: Coulometric cell Without diaphragm. 19. Detachable cable for Generator Electrode. 20. Sensor Electrode: Double platinum glass electrode. 21. Control: Stand alone with compact USB key board and Touch pad keys on display. 22. Display: Min 3.5 inches -1/4 VGA TFT color display with 320 x 240 Pixels with live titration curve. 23. Climate: Max. relative humidity 80 % 24. Ethernet Interface: For connecting a local network (LAN) 25. Measuring speed: Max. 1.5 mg/min. 26. A compact USB keyboard should be provided for alphanumeric entries of sample name, sample ID and sample weight. 27. DATA INPUT/OUTPUT & INTERFACE: Two RS232 port and two USB port for Connectivity to Balance, Printer for direct transfer of sample weight from the balance, Printer facility to print results. 28. Data Transfer: Test result and Method can be transferred in Pendrive in PDF and CSV format. 29. For future upgradation, compatibility with 21 CFR software to control the instrument via PC 30. For future upgradation, compatibility with Headspace Oven and Sample changer 31. POWER SUPPLY: By external multi-range power supply from 100 240 V, 50/60 Hz Input voltage: 12 Volt DC, 2500 mA Power consumption 30 W 32.The set consists of: a) Titrator b) Generator electrode without diaphragm c) Double Pt electrode d) Titration Vessel e) Magnetic Stirrer with pump f) one bottle of molecular sieve 33.Warranty: 12 months and Instrument Installation at site | 1 | Nos |
| 2 | NAS Analyser (1. Counter- Offline 2. Cleanliness Standards-ISO 4406, NAS 1638, SAE AS4059 3.Fluid Compatibility- Diesel & Hydraulic, Lubrication, Synthetic Oils 4.Technology- Digital Imaging Counter 5 Weight - 7 Kgs 6. Readings- 4 micron - 70 microns (4,6,14, 21,38 and 70 micron) 7. Viscosity- 320 cSt 8. Pump- Available, Continuous Operation 9. Root Cause Analysis- Fatigue Wear, Cutting Wear, Fibre Wear, Sliding Wear 10. Bubble Count Correction- Available, Counts bubbles separate to counter for more accuracy 11. Pressure- 0 - 2 BAR 12. Channels- 6 Channels 13. Online Data Storage- Available through QR Code 14. PLC Connection- Available 15. Data Storage- Available 16. Battery-Min. 5 Hours 17. Software- Available 18. Accessory Kit-Available 19. Extra (Accessory Kit) - Hose Pipes and Connectors X 2, Conical Flask X 2, Hand Pump X 1,. Micro Fibre Cloth X 1, Test Bottles X 2 20. Calibration- 24 Months (2 years ) 21. Warranty- 12 Month ( One Year ) 22. Installation- At Site) | 1 | Nos |
| 3 | Hot Air Oven Large (1. Temperature range: 50 deg * c to 250 deg * c +/-1% accuracy 2. Door wall properly insulated. 3. Inside chamber: Stainless steel inner size minimum: 18 * 18 * 24 inches 4. The instrument should have forced air circulation. 5. Power supply: 230/220 v, 50 Hz single phase AC 6. Instrument should be provided with a high temperature sensitive capillary type thermostat to control the temperature automatically. 7. Digital Temperature controller cum indicator with sensor. 8. Provision to run fan and heater or simultaneously. separately 9. Instrument should be provided with an operation and maintenance manual along with circuit diagrams. 10. Warranty: 12 months 11. Instrument Installation at site) | 1 | Nos |
13 Days Left