Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID3691918
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : 8825/token-139/2025-26
Last Date For Submission9th Apr, 2026
Opening Date11 Apr, 2026
Cost
Document Cost500.00
EMD100000.00
Estimated Cost5000000.00
Location
CityDelhi
StateDelhi

Register to see full details

BOQ Items
#ItemQtyUnits
1Dismantling and taking out old unserviceable LT panel of any type and shape after breaking of PCC foundation/platform and taking away from exisiting location after necessary disconnection of all out going and incomming cable joints, earth strips and making the surface smooth etc. complete all as specified and directed by Engr-in-Charge.12.00Each Job
2Supply,installation,testing,commissioning of factory made and tested, CPRI approved LT Panel, in door type, wall mounted of size 1700x400x1200 mm (LxWxH) suitable for 415 Volts 3 phase and neutral, 4 wire, 50 Hz, AC supply system having bus bar chamber with duly insulated electrolytic copper bus bar of capacity 400 amps rating insulated on DMC insulators with busbar chamber.The Panel shall be dust and vermin proof IP 42 class protection and made out of 2.00 mm thick CRCA sheet, front opening type with approns for cable entry, with proper ferrule and cable gland , internal wiring with PVC insulated multistranded copper conduction FRLS cable of adequate size but not less than 1.5 sqm. All steel metal works including frame shall be with anticorrossive coating with seven tank process and finally epoxy polyster powder coating of siemens grey RAL-7035 Shade complete all as specified and directed. The scope of work also comprising of the following:- (a) MCCB 250A, 4 pole,adjustable thermal magnetic type,415volts ,25 KA=01 No (for incoming) (b) MCB SPN 63 Amps 240 volts, 10KA, C series -13 Nos (Out going) (c) Insulated Copper Bus bar 400 Amp TPN, copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combbustible, track resist, high strenth DMC material. interconnection of all incomming & out goings =1 set of four (d) Voltmeter Digital 0-500 volts with integrated selector switch and PTS - 01 No (e) Ammeter Digital 0-400 Amps with integrated selector switch and CTS - 01 No (f) Set of indicating lamp(RYB) LED type -01 Note :- (i) The single phase prepaid KWh energy meter retreaved from existing LT panel must be fitted in the provisional space for prepaid meter in the new LT Panel - 011 nos (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) All out going feeder should be marked with quarter number. (iv) Testing certificate must be provided before installation (v) Rate quated are deemed to inclusive of all the fixture / fitting cater above. 6.00Each
3M&L for disconnecting all the cable connection from indoor LT Panel and servicing to Panel board of any size, opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable copper wiring kit and burn out unserviceable extended copper terminals/copper cable and replacing terminal with suitable size along with required nut bolt, washers and cleaning with air blower to serviceable parts like MCCB's, all terminals, replacement of damaged aluminium/copper lugs any discription of LT UG cable/ copper wire incomming and out going, welding of broken door with suitable hinges, replacement of defective copper wiring with suitable copper conductor with circuit indiator replacement of defective rubber beading,writing various feeder complete all as specified and as directed.10.00Each Job
4Material and labor for demolished the old floor and scrabing the wall surface, Removing the dust and waste material from site and making the good/smooth suface of floor/wall of LT panels Room by concreate and cement work (Hard standing and Plaster ) and applying two coat paint as per direction with white colour complete all as directed. NOTE :- (I) Contractor is advised to visit the site before quoting the rates.6.00Each Job
5Supply,installation,testing,commissioning of factory made and tested, CPRI approved LT Panel, in door type, wall mounted of size 1200x300x800 mm (LxWxH) suitable for 415 Volts 3 phase and neutral, 4 wire, 50 Hz, AC supply system having bus bar chamber with duly insulated electrolytic copper bus bar of capacity 250 amps rating insulated on DMC insulators with busbar chamber.The Panel shall be dust and vermin proof IP 42 class protection and made out of 2.00 mm thick CRCA sheet, front opening type with approns for cable entry, with proper ferrule and cable gland , internal wiring with PVC insulated multistranded copper conduction FRLS cable of adequate size but not less than 1.5 sqm. All steel metal works including frame shall be with anticorrossive coating with seven tank process and finally epoxy polyster powder coating of siemens grey RAL-7035 Shade complete all as specified and directed. The scope of work also comprising of the following:- (a) MCCB 160A, 4 pole,adjustable thermal magnetic type,415volts ,25 KA=01 No (for incoming) (b) MCB SPN 63 Amps 240 volts, 10KA, C series -04 Nos (Out going) (c) Insulated Copper Bus bar 250 Amp TPN, copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combbustible, track resist, high strenth DMC material. interconnection of all incomming & out goings =1 set of four (d) Voltmeter Digital 0-500 volts with integrated selector switch and PTS - 01 No (e) Ammeter Digital 0-400 Amps with integrated selector switch and CTS - 01 No (f) Set of indicating lamp(RYB) LED type -01 Note :- (i) The single phase prepaid KWh energy meter retreaved from existing LT panel must be fitted in the provisional space for prepaid meter in the new LT Panel - 04 nos (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) All out going feeder should be marked with quarter number. (iv) Testing certificate must be provided before installation (v) Rate quated are deemed to inclusive of all the fixture / fitting cater above. 6.00Each
9th Apr, 2026