| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Material and Labour for complete removal of existing any type of existing roof treatment including bedding layer of concrete/mud any thickness in cement mortar and including carefully removal of solar plates and refixing the same at same place after the execution of work disposed from MD land complete all as specified and as directed. | 1320.00 | Sqm |
| 2 | Material and Labour for cement concrete 1 : 2 : 4 type B-1 (using 20 mm graded stone aggregate) laid as in padding 50mm thick average over roof slabs for providing proper slope including finishing surface even and smooth without unsing extra cement with admixture of WPC liquid 150 ml per bag of cement complete all as specified. Note : WPC will be measured and paid separately. | 66.00 | Cum |
| 3 | Cleaning and preparation of the surface to receive Fosroc Proofex ORG or its equivalent in approved make water proofing system shall be a sound base, any crack shall be treated with cementious repair mortar of Fosroc Renderoc CS or epoxy crack filling mortar by proper grooving arrangement all as directed by engr - in charge. | 1320.00 | Sqm |
| 4 | Providing and laying / fixing TPO membrane of nonflammable waterproofing of roof which shall be a 1.5mm thick loose laid TPO membrane layers overlapped to achieve a minimum weld of 110mm, Hot air welding can be either handapplied or by means of automatic machines and the rolls either end are overlapped with layers of non-woven geotextilefiber, the separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane or its equivalent in approved make and the concrete substructure, the termination of Fosroc Proofex ORG or its equivalent in approved make by aluminium strip anchoring. Note: Work shall be executed by authorised applicator with prior experience of more than 5 years in applying similar system. | 1320.00 | Sqm |
| 5 | Material and Labour for dismantling loose concrete cover of RCC slab, ceiling , columns, beams,chajja, balconies, staircase and as direceted, roughening and cleaning concrete surfaces with steel wire brushes, removing of rust from existing steel surfaces with rust removers of SIKKA restoff 100 applied two coast @0.15kg/Sqm per coat of steel surface and cleaning all rust with steel wire brush and washed with water and allowed to dry incl Supply and Fixing welded fabric GI wire mesh or wire , size not less than 75 x 75 mm and 3 mm dia as reinforcement to concrete. After placing the additional re-inforcement, all concrete surfaces shall be throughly scurbbed with brushes, washed with water and allowed to dry to this surface , apply chenmical policrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of oridinary poartland cement 53 grade and 2 parts of ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2.2 to 2.5 kg per sqm by guniting machine and surfaces finished even and fair including necessary padding, shuttering form work etc and finally applying 5 mm thick cement plaster in CM 1:3 complete all as specified and directed by Engineer-in-Charge. | 350.00 | Sqm |