Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4374594 |
|---|---|
| Organisation Name | Delhi Development Authority |
| Tender Brief | Corrigendum : Earthing And Miscellaneous Repairing Work Of Street Light At Various Locations In East Zone Dda. |
| Last Date For Submission | 2nd Jun, 2026 |
| Opening Date | 03 Jun, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 56935.00 |
| Estimated Cost | 2846732.00 |
| City | Delhi |
|---|---|
| State | Delhi |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | 1.0) LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy 120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F. 0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K / 4000 K / 5700 K /6500 K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 C). (i) 120 Watt | 5 | Each |
| 2 | (ii) 150 Watt | 15 | Each |
| 3 | 2.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor Single core cable in the existing surface/recessed steel/PVC conduit/ Pole as required. a) 3 x 1.5 Sq.mm | 100 | Mtr. |
| 4 | 3.0) Providing and applying two coating of dielectric paint of existing street light poles including cleaning, surface preparation etc. As complete required. | 870 | Each |
| 5 | 4.0) Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A | 31 | Each |
5 Days Left