Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4881254
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Maint And Repairs/replacement Of Unserviceable Wiring, Mcbs, Mccbs, Dbs, Lights, Summer And Winter Appliances Including Atending Day To Day Complaints At Bana Singh Enclave, Phillaurah Enclave And Khyber Line Under Age E/m Of Ge (south) Delhi Cantt
Last Date For Submission5th Aug, 2026
Opening Date07 Aug, 2026
Cost
Document Cost500.00
EMD40000.00
Estimated Cost1990000.00
Location
CityDelhi
StateDelhi

Register to see full details

BOQ Items
#ItemQtyUnits
1Note: (i) The contractor or his authorized representative shall report daily to the Complaint Cell for collection of complaints and The contractor shall be required to attend complaints as and when intimated by the department through complaint slip , VYNUS , telephone or any otherauthorised means of communication .If it is not possible to rectify the same within timeline specified below, the matter along with detailed reasons shall immediately be brought to the notice of the Engineer-in-Charge by the contractor or his representative. If the Engineer-in-Charge is satisfied with the justification furnished, no recovery shall be effected on this account. (ii) (a) All No Light / Power Supply complaints shall be attended to and rectified within 01 hour, commencing from the date and time of issue/intimation of the complaint. Failure to attend the complaint within the stipulated period shall attract a penalty of Rs. 120/- for delay up to 04 hours and Rs. 240/- for delay beyond 04 hours, which shall be recovered from the contractor's dues. (b) All other routine maintenance complaints covered under the contract shall be attended to and rectified within 24 hours, commencing from the date and time of issue/intimation of the complaint. In case the complaint is not rectified within the stipulated period, a penalty of Rs. 120/- per complaint per day or part thereof shall be recovered from the contractor's dues.. However, labour charges for items covered under M&L , S&F , and In Repair shall be deemed to be included in the respective quoted rates. (iii) Items under this contract are of day-to-day nature and the complete scope/site cannot be forecast or handed over to the contractor at one time. The contractor shall therefore arrange adequate manpower, materials, and resources as per site requirements. In case the contractor fails to provide the required skilled labour in accordance with the contract provisions, suitable recoveries/penalties shall be levied as applicable.
2(iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge. (v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account.
3Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. 0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy 120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90 C). complete all as specified and as directed.700.00Each
4Supply and fix in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. 0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy 120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 C), complete all as specified and as directed.100.00Each
5S&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 15 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed.150.00Each
5th Aug, 2026

6 Days Left

WhatsApp