| Tender ID | 4055667 |
|---|---|
| Organisation Name | Indian Institute Of Technology |
| Tender Brief | Corrigendum : Providing, Installation, Testing And Commissioning Of Cassette Type Fcu In Server Room 2nd Floor Sit Building At Iit Delhi |
| Last Date For Submission | 4th May, 2026 |
| Opening Date | 05 May, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 7428.00 |
| Estimated Cost | 371412.00 |
| City | Delhi |
|---|---|
| State | Delhi |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supplying, installation, testing and commissioning of 4.0 TR nominal capacity with air quantity not less than 1200 CFM Chilled Water Ceiling Suspended Hydronic Cassette type fan coil unit, four (4) way directional flow, low noise, each complete with two (2) rows of deep chilled water cooling coil, multi-blade centrifugal fan, test reports from National Accreditation Board for Testing and Calibration Laboratories (NABL)/AHRI accredited lab, electronic air cleaning system, required set of ball valves with & without strainers & 2 way Motorized valve, insulated condensate drain pans with drain pump assembly & drain pump failure alarm, pipe connections through copper pipes, Infra-red remote control, Liquid Crystal Display (LCD), four (4) speed motor , fan four (4) direction air flow, auto swing louvre, decorative panel etc., condensation drain connections, all units shall be suitable for 220 +/- 10% Volts, 50 Hz, single phase power supply etc. complete as per specification. The wireless Remote temperature control / thermostat shall have memory back up for set point re-store in case of power failure and re-start. Four (4) hanger rods with required anchoring fasteners, hooks, washers etc. complete as per CPWD specification and as directed by Engineer-in-charge. Type test report shall be submitted before supply of material. | 2 | Each |
| 2 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. | ||
| 3 | 50 mm dia 'C' class with 50 mm thick insulation | 36 | Metre |
| 4 | 25 mm dia 'C' class with 50 mm thick insulation | 30 | Metre |
| 5 | Supplying, fixing, testing and commissioning of 50 mm dia. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water water circulation, in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. | 2 | Each |