Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4025311 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Re-location Of Solar Plant From Building No P-88 To Building No 87 At Subroto Park |
| Last Date For Submission | 13th May, 2026 |
| Opening Date | 16 May, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 57600.00 |
| Estimated Cost | 2880000.00 |
| City | Delhi |
|---|---|
| State | Delhi |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | M&L for dismantling the existing Solar Plant installed at Bldg No P-88 with due care without damaging the its panels /euipments etc, removing of framed structures, cabling etc.shifting the same to bldg No 87 and installation complete including string formation, installation of AJB with proper string termination and all other equipments with necessary DC and AC connections, testing and comissioning of the complete system with integration to existing system installed at various locations of Subroto Park. The details are as under : - (a) Solar Panels-146 Nos with array junction box, AC/DC cabling etc. (b) Inverter 50 KW string inverter including DC and AC isolation (c) Water Tanks 100 lts capacity. (d) Control Panels. (e) Transmission system and WMS System (f) Reinstallation /augmentation of earthing system and lighting arrestor including required earthing as per recommendations. (g) MC4 connectors, lugs, glands etc as per requirement at site. (h) Note - (i) The rates for transportation of entire system to new locations are deemed to be included in the above rates. (ii) Re-installation shall be include provision of PCC foundation 1:2:4 for module mounting structure including excavation, shuttering curing foundation, mounting structures, nuts & boltswith grouting.and complete re-establishment of electrical connections. (iii) Testing and commissioning synchronization, performance validationof the solar plant after installation shall be inclusive of quoted rates. (iv) DC Solar cable min 4 sqmm UV resistant as per requirement. (v) Communication cable (RS485) as per requirement (vi) GI cable tray and conduits with necessary support. (vii) The bidder shall ensure that the relocated system maintains the existing electrical configuration including string sizing, inverter loading, protection scheme and communication system (Modbus/RS485) as per existing design (viii) The bidder to provide the complete drawing of layout of system as per available space on Bldg No 87 for approval of Accepting officer (ix) Any other item required for sucessful completion and proper performance of system deemed to be included in the rated quoted for the above. | 1.00 | Each Job |
| 2 | Supply, fabrication and installation of galvanised (Min 80 Microns) iron frame structure as per recommended size of material and installation of HDGI modules mounting structure complete as per approve drawing complete all as specified and directed. | 1000.00 | Kg |
| 3 | Supply, laying, jointing and testing of LT cable XLPE Insulated, screened, PVC bedded, galvanized steel strips armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 50 sq mm 3 core complete all as specified and directed with necessary cable glands at end, aluminium lugs for connecter complete all as specified and directed. | 100.00 | RM |
| 4 | Excavation in trenches in hard / dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, laying of cable etc not getting out complete all as specified and directed. | 12.00 | Cum |
| 5 | Returning , filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil complete all as specified and directed. | 7.00 | Cum |