Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID3587535
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Repair/maint Of Central Ac Plant Installed At Tech Building Of Camero Area And Wac Area Under Ge (af) Subroto Park, Delhi Cantt-10
Last Date For Submission2nd Apr, 2026
Opening Date09 Apr, 2026
Cost
Document Cost500.00
EMD56000.00
Estimated Cost2800000.00
Location
CityDelhi
StateDelhi

Register to see full details

BOQ Items
#ItemQtyUnits
1Material & Labour for servicing of AHU for 20000 CFM AC plant installed at OPS room comprising of cleaning the air filter/cooling coil, cleaning of fresh air duct/grill with chemical followed with pressurised water jet, greasing of AHU motor, tightening of belts, checking the functioning of 3 way motorised mixing valve, tightening of all nut/bolts for noiseless operation of AHU complete all as specified and as directed by the Engineer-in-Charge. Note: Servicing shall be carried during the commencement of contract and second servicing shall be carried out after six months from first servicing.2.00Each Job
2Material & Labour for servicing to condensor (3 Nos sets) of 3 x 25 TR AC plant installed at OPS Room including opening the end plates, carrying out the descaling with descaling compound and pull through with nylon brush in each tubes, cleaning thoroughly with water, refixing the end plates to its existing position to ensure leak proof area complete all as specified and directed by the Engineer-in-Charge. Note: Servicing shall be carried during the commencement of contract and second servicing shall be carried out after six months from first servicing.2.00Each Job
3Material & Labour for repair to suction & discharge valve of compressor 3x25 TR of capacity by means of replacing the teflon washer sheet, suction & discharge valve ring, spring, 'O' rings, gaskets etc complete and testing for proper holding of valve, leak testing etc complete all as specified and as directed by the Engineer-in-Charge. NOTE: The rate inclusive of suction & discharge valve which is considered as one job.2.00Each Job
4Supply & Fixing in Replacement of panel air filters, dry type, washable, rated air flow capacity 1600 CFM 99.9%, down to particle 20 micron of Suitable sizes or nearest for AHU of central AC plant complete all as specified and directed by the Engineer-in-Charge.10.00Each
5Supply and fixing in replacement of liquid line Y strainer for AHU 20000 CFM and condenser pipe line including welding, leak testing and leak arrest complete all as specified and directed by the Engineer-in-Charge..1.00Each
2nd Apr, 2026