Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4156162 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/ Maint Of Various Ductable / Cassette / Tower Type Acs In The Area Of Camero Under Ge (af) Subroto Park |
| Last Date For Submission | 27th May, 2026 |
| Opening Date | 30 May, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 80000.00 |
| Estimated Cost | 4000000.00 |
| City | Delhi |
|---|---|
| State | Delhi |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Servicing of tower /cassette AC/Ductable type split AC/package type AC/Clod storage of capacity 3/3.5/4.5/8.5 of any make at different locations at Subroto Park, tersting the unit complete with the following tasks:- (a) Overhauling and servicing (b) Inspection opening washsing the condesnor coil and cooling coil with chemical followed with pressurized water jet complete. (c) Inspection of leakage of refrigerent in the system (d) Checking the operation of blower motor, condesnor morto and swing motor for noise free operations. (e) Oilling of condesnor/blower motors and checking the earth continuity. (f) Inspection of all electerical parts/connections and remove if any defect. (g) Checking the functioning of electronic remote control unit to ensure satisfactory functioning of unit complete all as specified and as directed by Engr -in-Charge. Note:- (a) Spare parts shall be measured and pair separately. (b) Repeated complaints of same air conditioner will not be measured again and no extra payment will be made. (c) Rate of vist against complaint deemed to be included in the rate quoted above. Note - The contractor to maintain the job card of each AC having complete details of each AC & Schedule of repari & serving, the format of job card to be approved by Engineer in charge. | 60.00 | Each Job |
| 2 | Supply and fixing in replacement of the following UNSV spare parts for Tower/Casette/Ductable type split AC/Package type AC of capacity 3/3.5/4/5.8.5 TR air Conditioners of any make & complete all as specified and direted by Engr -in-Charge (a) Single phasing preventor as per existing size and capacity | 15.00 | Each |
| 3 | All as per item No 2 here in before but contactor single phase as per existing size complete all as specified and directed. | 15.00 | Each |
| 4 | All as per item No 2 here in before but contactor three phase as per existing size complete all as specified and directed. | 10.00 | Each |
| 5 | All as per item No 2 here in before but Running Capacitor as per existing size & capacity complete all as specified and directed. | 30.00 | Each |
6 Days Left