Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3879044 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair Maintenance Of 3 X 11 Tr Ac Plant At Hqtg Eme Cold Storage Room Installed At 226 Asc Supply Depot And Ambiators Installed At 505 Abw Under Ge (u) Pm Delhi Cantt10 |
| Last Date For Submission | 27th Apr, 2026 |
| Opening Date | 30 Apr, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 56000.00 |
| Estimated Cost | 2800000.00 |
| City | Delhi |
|---|---|
| State | Delhi |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Disconnecting electrical connections of package type AC plant for servicing of capacity 11 TR including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keeping the AC unit in satisfactory working condition after necessary servicing as required and refixing the same in existing position complete all as specified and as directed . | 4 | Each Job |
| 2 | M&L for rectifying electrical wiring fault of package type AC plant of capacity 11 TR and make them functional and also carry out the required repair complete all as specified and as directed. | 6 | Each Job |
| 3 | M&L for Disconnecting from mains/ taking out existing unserviceable/defective 3 phase, scroll compressor of Package type AC Plant of capacity 5.5 TR and supply and fixing new scroll compressor including making connections of suction and discharge copper pipe by brazing, pressure testing by Nitrogen gas, rectification of leakage if any, vacuumising and initial charging of refrigerant gas R-22, commissioning & testing for satisfactory working complete all as specified and directed by Engineer-in-Charge. (Make:- Emerson Model No. ZR72KC-TFD-522 or equivalent model of make Voltas/ Blue Star/ Tecumseh.) (Note :- The rates quoted by the contractor shall deemed to be included the cost of initial charging of Refrigerant gas R-22.) | 4 | Each Job |
| 4 | S&F in repair of liquid line drier filter of capacity 5.5 TR complete all as specified and directed by engineer in charge (Make - Crompton greaves/ Kirloskar/ KBS) | 4 | Each |
| 5 | S&F in repair of condenser fan motor of capacity As per existing motor complete all as specified and directed by engineer in charge (Make - Crompton greaves/ Kirloskar/ KBS) | 3 | Each Job |
6 Days Left