Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Municipal Council
Tender ID3976953
Organisation NameMunicipal Council
Tender BriefCorrigendum : Supply, Installation, Testing and Commissioning Of Air Ventilation System At Basement I And Basement Ii Of 160 Nos Type Iii Flats At Sector Vi Pushp Vihar Saket New Delhi
Last Date For Submission5th May, 2026
Opening Date05 May, 2026
Cost
Document Cost0.00
EMD637547.00
Estimated Cost31877325.00
Location
CityDelhi
StateDelhi

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply, Installation, Testing & Commissioning of AMCA Certified (For Air and Sound Performance) tube/Vane axial flow fans of different capacities in standard GI/M.S. construction as mentioned below. Entire fan model and AMCA Seal shall appear in technical submittal of fan. Housing to be made from either galvanized steel with a coating of Z275 or mild steel that is hot dipped galvanized to DIN EN ISO 1461 and complete with bird screen at fan outlet. Fans shall be EN Rated for high temperature as suitable for operation at a minimum of 250 C for 2 hours. The electric motor coupler shall be IE- 03/IE-04 squirrel cage induction type conforming to IS-325, IP-55 rated with class `H' insulation. Fan rpm: The speed of the fans shall not be more than 1450 RPM; however fans with 8000 CFM and below may be selected at 2900 RPM. Fan total efficiency should not be less than 65%, and noise level to be 80 db @ 3m distance when measured under hemispherical reverberant room conditions. Quoted price shall be inclusive of sound attenuator at the outlet/inlet of the fan to achieve desired sound levels. Fans mentioned as outdoor type shall be good for outdoor installation with proper cowl and mounting arrangement as per approved shop drawings. Fans shall be as per specifications and design drawings. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans. Axial Flow Fans shall follow the design parameters as mentioned below:
221500 CFM, SP 25 mm wg (For upper basement)16.00Nos
315000 CFM, SP 25 mm wg (For lower basement)16.00Nos
4Supply, Installation, Testing & Commissioning of AMCA Certified (For Air and Sound Performance) tube/Vane axial flow fans of different capacities in standard GI/M.S. construction as mentioned below. Entire fan model and AMCA Seal shall appear in technical submittal of fan. Housing to be made from either galvanized steel with a coating of Z275 or mild steel that is hot dipped galvanized to DIN EN ISO 1461 and complete with bird screen at fan outlet. Fans shall be EN Rated for high temperature as suitable for operation at a minimum of 250 C for 2 hours. The electric motor coupler shall be IE- 03/IE-04 squirrel cage induction type conforming to IS-325, IP-55 rated with class `H' insulation. Fan rpm: The speed of the fans shall not be more than 1450 RPM; however fans with 8000 CFM and below may be selected at 2900 RPM. Fan total efficiency should not be less than 65%, and noise level to be 80 db @ 3 m distance when measured under hemispherical reverberant room conditions. Quoted price shall be inclusive of sound attenuator at the outlet/inlet of the fan to achieve desired sound levels. Fans mentioned as outdoor type shall be good for outdoor installation with proper cowl and mounting arrangement as per approved shop drawings. Fans shall be as per specifications and design drawings. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc prior to order the fans. Axial Flow Fans shall follow the design parameters as mentioned below: Each fan Capacity 15000 CFM, SP 30 mm wg10.00Nos
5Supply, Installation, Testing & Commissioning of AMCA Certified (For Air and Sound Performance) tube/Vane axial flow fans of different capacities in standard GI/M.S. construction as mentioned below. Entire fan model and AMCA Seal shall appear in technical submittal of fan. Housing to be made from either galvanized steel with a coating of Z275 or mild steel that is hot dipped galvanized to DIN EN ISO 1461 and complete with bird screen at fan outlet. Fans shall be EN Rated UL Listed for high temperature as suitable for operation at a minimum of 250 C for 2 hours. The electric motor coupler shall be IE- 03/IE-04 squirrel cage induction type conforming to IS-325, IP-55 rated with class `H' insulation. Fan rpm:The speed of the fans shall not be more than 1450 RPM, however fans with 8000 CFM and below may be selected at 2900 RPM. Fan total efficiency should not be less than 65%, and noise level to be 80 db as per table below @ 3 m distance when measured under hemispherical reverberant room conditions. Quoted price shall be inclusive of sound attenuator at the outlet/inlet of the fan to achieve desired sound levels. Fans mentioned as outdoor type shall be good for outdoor installation with proper cowl and mounting arrangement as per approved shop drawings. Fans shall be as per specifications and design drawings. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans. Axial Flow Fans shall follow the design parameters as mentioned below: Each fan Capacity 15000 CFM, SP 30 mm wg 5.00Nos