| 1 | SRTC of indoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for Gym, health club, swimming pool , admin building, badminton court, gust house and AC of club , card room , billyyard and bar )
A) INCOMER
i) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-3 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.
B) BUSBARS
i) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )
C) OUTGOINGS
i) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 8 Nos.
| 1 | Each |
| 2 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for cricket ground high mast)
A) INCOMER
i) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.
B) BUSBARS
i) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )
C) OUTGOINGS
i) 100 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 4 Nos.
ii)ii) 16 AMP DP MCB,10KA -2 Nos. | 1 | Each |
| 3 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for jogger park )
A) INCOMER
i) 200 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 200/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.
B) BUSBARS
i) 375 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )
C) OUTGOINGS
i) 63 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 2 No.
iii) 32 AMP DP MCB,10KA -2 Nos.
iii) 16 AMP SP MCB,10KA -1 Nos. | 5 | Each |
| 4 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for gym , sauna steam, change room of swimming pool )
A) INCOMER
i) 250 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 400/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.
B) BUSBARS
i) 400 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )
C) OUTGOINGS
i) 100 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 4 No.
ii) 63 AMP FP MCB,10KA -3 Nos.
| 1 | Each |
| 5 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (forswimming pool plant room)
A) INCOMER
i) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 150/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.
B) BUSBARS
i) 200 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )
C) OUTGOINGS
i) 7.5 HP DOL starter - 2 No.
ii) 5 HP DOL starter - 1 No.
iii) 40 AMP FP MCB,10KA -1 No.