Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Reserve Bank Of India
Tender ID4858788
Organisation NameReserve Bank Of India
Tender BriefE-tender For Electrical Renovation Work At Basement Area Of Main Office Building, New Delhi
Last Date For Submission17th Aug, 2026
Opening Date18 Aug, 2026
Cost
Document Cost0.00
EMD0.00
Estimated Cost514000.00
Location
CityDelhi
StateDelhi

Register to see full details

BOQ Items
#ItemQtyUnits
1Wiring and Switchboards
2Lights (Primary) and Fans point Supply, installation, testing and commissioning (SITC) of wiring for tube lights, ceiling fans and exhaust fan point from respective switchboards, using 2 x 1.5 sq mm and 1.0 sq mm, 1100 Volts grade PVC insulated single core multistranded unsheathed copper FRLSH wires, including main circuit wiring from the MCB DB box to respective switchboard in suitable dia medium duty MS conduit with required accessories like bends, tees, junction boxes etc., in partly concealed/ partly surface manner (as the case may be) and making good the chases with cement plaster of suitable thickness, merging with adjoining area. The surface shall be finished by skilled persons for getting a smooth and merging surface. Rate shall include for provision of modular type 10 Amp Switches with 6 Amp Sockets on switchboards (as mentioned above) on factory fabricated GI box (of same Make, as switches plate) and required size mounting plate fixed on respective approved company make boxes concealed in wall. All the fan points need to be terminated on a 3-terminal ceiling rose on a junction box. All tube light points need to be terminated with providing a tee-cover. Necessary circuit wiring from D.B. upto the switch board for above items rate shall be done with (2 x 2.5 and 1 x 1.5) 1100 Volts grade PVC insulated single core multistranded unsheathed copper FRLSH wires. Final connections also shall be made with flexible wires (of suitable rating) etc. Load on each circuit shall not be more than 800 Watts. Use blank plates on switchboards wherever required.89.000Nos
3Lights (Secondary) Point Same as Item at S.N. 1.01 above, but looped from primary light point, and controlled through same 10 Amp switch of the switchboard.14.000Nos
4Set of two 6 Amp Plug-point (Primary) SITC of (a pair) independent two 3-pin 6 Amp modular socket controlled by two 10 Amp modular switch housed in metal GI box and modular plate (both of same Make) of suitable size and wired using 2 x 2.5 + 1.5 sq. mm 1100 Volts grade PVC insulated single core multistranded unsheathed copper FRLSH wire, from mains MCB DB laid through recessed medium duty MS conduit pipe complete with all accessories or on surface, as per site requirement as directed by Bank's Engineer. Light & fan switchboard, as per Item 1.01, and Set of two 6 Amp Plug-points, as per Item 1.02, shall be on same main circuit.19.000Nos
5Set of two 6 Amp Plug-point (Secondary) SITC of (a pair) independent two 3-pin 6 Amp modular socket controlled by two 10 Amp modular switch housed in metal GI box and modular plate (both of same Make) of suitable size and wired using 2 x 2.5 + 1.5 sq. mm 1100 Volts grade PVC insulated single core multistranded unsheathed copper FRLSH wires, looped from nearest primary point (as per S.N. 1.02) laid through recessed MS medium duty conduit pipe complete with all accessories or on surface, as per site requirement as directed by Bank's Engineer.19.000Nos
17th Aug, 2026

41 Days Left

WhatsApp