Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Public Works Department
Tender ID4245466
Organisation NamePublic Works Department
Tender BriefSupply , Installation, Testing And Commissioning Of Split Type Ac With Stabilizer At Various Offices Under M-south Electrical Maintenance Division
Last Date For Submission18th May, 2026
Opening Date18 May, 2026
Cost
Document Cost0.00
EMD5517.00
Estimated Cost275840.00
Location
CityDelhi
StateDelhi

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only
21.5 TR with 5 Star BEE Rating5.00Nos.
3Supplying and fixing voltage stabilizer input power 160-290v, output; 230+/- 8%, Intelligent Time Delay system-Gives the Compressor proper balancing When Mains On Returns, Digital Display with high/low voltage protection i/c suitable for 1.5Ton Air-Conditioners (minimum 4 KV)and Thermal overload protection etc. complete as required.5.00Nos.
4Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and Liquid lines, all accessories as per specifications etc. as required : i/c credit of old dismental material as and where basis etc.
56.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation35.00Mtrs.