| 1 | Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed. | 3140.00 | PER POINT |
| 2 | M & L for servicing of ceiling fans/wall mounted 1200/1400mm sweep of any make/model, including removal of existing winding carefully from the slots,cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation with super enmelled copper number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including complete all as specified and directed. | 1500.00 | EACH JOB |
| 3 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and modular sunken boxes, its accessories,modular plate 4,6,8,10,12 & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One light/fan/bell/exhaust point controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 1000.00 | PER POINT |
| 4 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sunken for boxes, its accessories,modular plate 4,6,8,10,12 & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One 5 amp same board controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 120.00 | PER POINT |
| 5 | M&L for drawing of wire RYB for phase,black for neutral,green for earth wire including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 25 mm OD and including cutting chases for conduits and sinkings for boxes, its accessories modular plate 4,6,8,10,12& including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for One 5 amp Indepedent board controlled by one switch Note: per point lenght of cable should be 7 to 15 mtr . 2.light circuit will be laid seperate conduit not including 5amp, 15 amp coduit complete all as specified and directed. | 350.00 | PER POINT |